BOECO GP Series Bottle-top Dispenser — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO GP Series Bottle-top Dispenser

Reference 16

Bottle-top dispenser by BOECO Germany

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
16
Category
Pipettes & Liquid Handling
Product range
Bottle-Top Dispenser

Technical specifications

Code
Bottle neck / Dispenser
BOE 1670110
38/45
BOE 1670120
40/45
BOE 1670150
25/32
BOE 1670155
28/32
BOE 1671090
Drying tube
BOE 1671682
Ventilation plug for micro filter (PP) with Luer-cone and sealing ring
BOE 1671683
Sealing ring for valve block (PTFE) for dosing highly volatil media
Show 14 more specifications
BOE 1678132
Flexible discharge tube, PTFE, 80 cm, for volume 2/5/10 ml
BOE 1678134
Flexible discharge tube, PTFE, 80 cm, for volume 25/50/100 ml
BOE 1678210
Telescopic filling tube 70-140 mm for volume 2/5/10 ml
BOE 1678212
Telescopic filling tube 125-240 mm for volume 2/5/10 ml
BOE 1678214
Telescopic filling tube 195-350 mm for volume 2/5/10 ml
BOE 1678216
Telescopic filling tube 250-480 mm for volume 2/5/10 ml
BOE 1678218
Telescopic filling tube 170-330 mm for volume 25/50/100 ml
BOE 1678220
Telescopic filling tube 250-480 mm for volume 25/50/100 ml
BOE 9900110
1,0 - 10,0 ml
BOE 9900225
0,2 - 2,0 ml
BOE 9900550
0,5 - 5,0 ml
BOE 9901100
10,0 - 100,0 ml
BOE 9902525
2,5 - 25,0 ml
BOE 9905050
5,0 - 50,0 ml
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO GP Series Bottle-top Dispenser

A service visit on the BOECO GP Series Bottle-top Dispenser covers gravimetric calibration at several volumes following ISO 8655, replacement of seals and O-rings, cleaning and decontamination, and a leak test.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Pipettes like the BOECO GP Series Bottle-top Dispenser are typically calibrated every three to twelve months depending on use, following ISO 8655, with a quick gravimetric check by the user in between.

  • Gravimetric calibration at nominal and partial volumes (ISO 8655)
  • Seals, O-rings and piston inspected and replaced when worn
  • Cleaning and decontamination of the lower parts
  • Leak test and tip-ejector check

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO GP Series Bottle-top Dispenser

When BOECO GP Series Bottle-top Dispenser fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

Common pipette faults are leaking seals, contaminated or corroded pistons, damaged tip cones, and volume settings that no longer deliver within tolerance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO GP Series Bottle-top Dispenser

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Use tips recommended for the pipette and fit them with a firm, straight press: ill-fitting tips are the most common cause of inaccuracy.

  3. Hold the pipette vertically after aspirating — a drop forming at the tip indicates a leak.

  4. Weigh a few dispensed volumes of distilled water on an analytical balance and compare them with the set volume.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO GP Series Bottle-top Dispenser.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO GP Series Bottle-top Dispenser and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO GP Series Bottle-top Dispenser

AxiTech supplies BOECO GP Series Bottle-top Dispenser together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO GP Series Bottle-top Dispenser

AxiTech supplies the BOECO GP Series Bottle-top Dispenser (reference 16) in Lebanon, with delivery, installation and commissioning. Add it to your request list or send us the reference to receive a quotation — nothing is charged online.