0.1° Resolution K-Type Thermocouple Thermometer with CAL Button — main photograph
Hanna InstrumentsAvailability: Supplied to order

0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

Reference HI93531N

The HI93531N 0.1° Resolution K-Type Thermocouple Thermometer is a digital, waterproof thermometer. This meter offers high accuracy temperature measurements using a wide variety of interchangeable K-type probes. HI93531N allows users to perform a one-point calibration in a 0°C ice bath. All readings are displayed on the backlit LCD, along with the high and low temperatures, temperature units, and a battery indicator upon startup.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI93531N
Category
pH, Conductivity & Water Analysis

Features

  • One-point calibration
  • Backlit display
  • High and low-temperature display

Technical specifications

Note
(*) Range may be limited by probe
Range
-200.0 to 999.9°C / 1000 to 1371°C -328.0 to 999.9°F / 1000 to 2500°F
Weight
235 g (8.3 oz.)
Battery
3x1.5V AA (IEC LR6) batteries, approx. 500 hours of continuous use (BL off)
Auto-Off
user selectable: 60 min or disabled
Warranty
2 years
Dimensions
150 x 80 x 36 mm (5.9 x 3.1 x 1.4)
Resolution
0.1°C (-149.9 to 999.9°C) 0.2°C (-200.0 to -150.0°C) / 1°C (outside) 0.1°F (-24.9 to 999.9°F) 0.2°F (-249.9 to -25.0°F) 0.3°F (-328.0 to -250.0°F) / 1°F (outside
Show 3 more specifications
Environment
-10 to 60°C (14 to 140°F) RH 100%
Accuracy (@20˚C/68˚F)
±0.5°C (-100.0 to 999.9°C) / ±1°C (outside) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside) excluding probe error
Typical EMC Deviation Probe
±3°C / ±6°F with HI 766 K-thermocouple probe
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

A service visit on the Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button covers the meter and its probes: electrode condition and response, calibration with fresh certified standards, a check of the meter input with a signal simulator where applicable, and the cables, connectors and batteries.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

A meter like the Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button is calibrated by its user before use or daily, as the method requires; a service check once a year confirms the instrument itself and identifies probes that no longer calibrate within specification.

  • Electrode and probe inspection, cleaning and response check
  • Calibration with fresh, certified buffers or standards
  • Meter input verified with a signal simulator where applicable
  • Cables, connectors, batteries and data logging checked

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

When Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

With meters the fault is usually in the probe rather than the instrument: a slow or drifting electrode, a clogged junction, a damaged cable or connector, or calibration solutions that have expired.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Calibrate with fresh, in-date solutions poured into clean beakers — never re-use solution or calibrate directly from the bottle.

  3. Inspect the probe: clean the sensing element and junction, refill or replace the electrolyte where the design allows, and check the cable and connector for damage.

  4. If calibration still fails, try a known-good probe on the same meter to tell a probe fault from a meter fault.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

AxiTech supplies Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the Hanna Instruments 0.1° Resolution K-Type Thermocouple Thermometer with CAL Button

1° Resolution K-Type Thermocouple Thermometer is a digital, waterproof thermometer. This meter offers high accuracy temperature measurements using a wide variety of interchangeable K-type probes.