10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes — main photograph
RadwagAvailability: Supplied to order

10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

Reference PA-203-0004

The pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product. The pipettes represent a new line of the ' liquid handling ' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
PA-203-0004
Category
Laboratory Balances

Overview

Large and readable display that is fully visible during pipetting; Innovative soft grip preventing heat transfer to the pipette inside; Low pressure required to use the pipette reduces the risk of RSI; Simple click mechanism for changing the pipette volume; Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure; Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion; Ultra UV resistance; Convenient button for changing the tips; Compatible with most of the tips available on the market.

Features

  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.

Technical specifications

Tips
300 μl
Volume
10 – 100 μl
Random error
1,5% / 0,15%
Systematic error
3,0% / 0,8%
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

A service visit on the Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes covers gravimetric calibration at several volumes following ISO 8655, replacement of seals and O-rings, cleaning and decontamination, and a leak test.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Pipettes like the Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes are typically calibrated every three to twelve months depending on use, following ISO 8655, with a quick gravimetric check by the user in between.

  • Gravimetric calibration at nominal and partial volumes (ISO 8655)
  • Seals, O-rings and piston inspected and replaced when worn
  • Cleaning and decontamination of the lower parts
  • Leak test and tip-ejector check

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

When Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

Common pipette faults are leaking seals, contaminated or corroded pistons, damaged tip cones, and volume settings that no longer deliver within tolerance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Use tips recommended for the pipette and fit them with a firm, straight press: ill-fitting tips are the most common cause of inaccuracy.

  3. Hold the pipette vertically after aspirating — a drop forming at the tip indicates a leak.

  4. Weigh a few dispensed volumes of distilled water on an analytical balance and compare them with the set volume.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

AxiTech supplies Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

The pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.