BOECO Autoclave BTE-23D — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Autoclave BTE-23D

Reference BOE 8902300

Steam steriliser by BOECO Germany: sterilisation temperature 121 °C and 134 °C.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 8902300
Category
Autoclaves & Steam Sterilizers
Product range
Autoclaves & Steam Sterilizers

Features

  • Three times fractionated pre-vacuum
  • Stainless steel chamber
  • LCD display
  • Equipped with high quality and high performance pump
  • 1 tray holder, 1 tray handle and 3 trays included
  • High quality water pump and valves
  • Independent steam generator
  • Two samples self-calibration
  • Overhead type water storage tank, easy to clean.
  • Drying procedure: Dry by vacuum.
  • Sterilization temperature: 121°C and 134°C
  • Test programs: Helix test, B&D test and Vacuum test.
  • Sterilization cycles: 9 cycles are available and 3 test programs.
  • It only have several buttons, very easy to use, any people can run it easily.
  • All cycles are fully automatic; there is no need for human intervention in cycle management.
  • Pressure protection locking system that ensures the door will not be opened once there is any pressure in chamber.
  • Sterilization documentation: Integrated Micro Printer and USB port to store the information of the programme cycle in flash memory.
  • The sterilization time and dry time can be adjusted by manual, ensure user obtain best sterilization effects according to private requirements.
  • Malfunction detection system, corresponding error code will be showed on the display once there’s something goes wrong.
  • Warning system prevents starting a cycle if door is not properly locked.
  • Triple Threat Protection for overheating and overpressure. The pressure protection system will automatically cut off the electricity supply once the temperature of chamber inside is abnormally. Motorola pressure sensor is used to accurately sense the state of pressure inside chamber. Temperature control system is using high quality PT1000 temperature sensor, it is high precision, reliable service and prompt measure, ensure accurate and timely transmission of temperature fluctuation. The safety valve will release steam in case the pressure inside chamber exceed normal levels.
  • Conform to CE and EN13060
  • Manufactured under ISO 9001 and ISO 13485 norms
  • Chamber Size: ø 247 x 460 mm (23 L)
  • External dimension: 690 x 480 x 455 mm, Netweight 51 kg
  • Packing box 750x560x460 mm, Grossweight 58 kg
  • Power: 220V, 50/60 Hz or 110V, 60HZ

Technical specifications

PRION
134°C
Program
Temperature
B&D TEST
134°C
SOLID 121
121°C
SOLID 134
134°C
Helix TEST
134°C
LIQUID 121
121 °C
LIQUID 134
134°C
Show 4 more specifications
WRAPPED 121
121°C
WRAPPED 134
134°C
TEXTILE 121 (or wrapped)
121°C
TEXTILE 134 (or wrapped)
134°C
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Autoclave BTE-23D

A service visit on the BOECO Autoclave BTE-23D covers calibration of the temperature and pressure sensors, the door seal, lock and safety valve, the steam generator, vacuum system, drains and filters, and a recorded test cycle.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Steam sterilisers like the BOECO Autoclave BTE-23D are normally serviced once or twice a year and revalidated every year, while users run the routine tests their class requires — for Class B units, a daily steam-penetration (Bowie-Dick or Helix) test and a regular vacuum leak test.

  • Temperature and pressure sensors calibrated
  • Door seal, locking mechanism and safety valve checked
  • Steam generator descaled, filters and drains cleaned
  • Test cycles run and recorded, including vacuum leak and Bowie-Dick tests on Class B models

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Autoclave BTE-23D

When BOECO Autoclave BTE-23D fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On steam sterilisers the common faults are failing door seals and locks, scale in the steam generator, blocked drains and filters, vacuum pumps that no longer reach their set point, and drifting temperature or pressure sensors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Autoclave BTE-23D

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Inspect and clean the door gasket and the chamber drain filter: debris on either causes most pressure and vacuum errors.

  3. Check the water quality and level in the reservoir — tap water or a low level leads to scale, heating faults and aborted cycles.

  4. Run the manufacturer's test cycle (vacuum leak or Bowie-Dick test on Class B models) and keep the printout for the engineer.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Autoclave BTE-23D.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Autoclave BTE-23D and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Autoclave BTE-23D

AxiTech supplies BOECO Autoclave BTE-23D together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Autoclave BTE-23D

Key specifications of the BOECO Autoclave BTE-23D, according to the manufacturer: sterilisation temperature 121 °C and 134 °C.