BOECO Electronic Pipettes — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Electronic Pipettes

Reference BOE 9650010

Light weight and ergonomic design with comfortable operations help to avoid Repetitive Strain Injuries (RSI)

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 9650010
Category
Pipettes & Liquid Handling
Product range
Electronic Pipettes

Overview

Modes

Every package includes: BOECO Electronic Pipette, Multiplug Battery Charger (EU, UK, US), Li-ion battery, spanner tool, manual, quality-certificate.

Manufactured in accordance with ISO 9001:2008 and ISO 13485:2003 quality standards

Features

  • Color coded tip ejector for easy identification
  • Hi-resolution color graphic interface with real time display of pipetting operation.
  • User friendly intuitive interface. Easy selection of all modes.
  • Most reliable 3-point calibration method ensuring accuracy and consistency in pipetting results for longer time.
  • Secured calibration with password protection
  • Saves power by switching to Standby Mode if the pipette is not in use for long time.
  • Favourite program can store frequently used sequence steps for smoother handling and complex process.
  • Bottom assembly autoclavable
  • Fast battery charging via charger with USB cable
  • Favourites
  • Pipetting
  • Reverse Pipetting
  • Multi Dispensing Sub Mode: Repeat Dispense, Auto Dispensing, Sequence - Dispensing
  • Diluting Sub Mode: Diluting + Mixing
  • Mixing Sub Mode: Mixing, Pipetting + Mixing, Diluting + Mixing
  • Settings
  • Calibration

Technical specifications

Cat-No
Channel
Power
4,2 V / 1150 mAh Li-ion battery
BOE 9650010
1-ch
BOE 9650100
1-ch
BOE 9650220
1-ch
BOE 9651100
1-ch
BOE 9655000
1-ch
Battery usage duration
6 hours of continuos usage
Show 1 more specification
Battery charging duration
2 hours for full charge
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Electronic Pipettes

A service visit on the BOECO Electronic Pipettes covers gravimetric calibration at several volumes following ISO 8655, replacement of seals and O-rings, cleaning and decontamination, and a leak test.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Pipettes like the BOECO Electronic Pipettes are typically calibrated every three to twelve months depending on use, following ISO 8655, with a quick gravimetric check by the user in between.

  • Gravimetric calibration at nominal and partial volumes (ISO 8655)
  • Seals, O-rings and piston inspected and replaced when worn
  • Cleaning and decontamination of the lower parts
  • Leak test and tip-ejector check

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Electronic Pipettes

When BOECO Electronic Pipettes fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

Common pipette faults are leaking seals, contaminated or corroded pistons, damaged tip cones, and volume settings that no longer deliver within tolerance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Electronic Pipettes

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Use tips recommended for the pipette and fit them with a firm, straight press: ill-fitting tips are the most common cause of inaccuracy.

  3. Hold the pipette vertically after aspirating — a drop forming at the tip indicates a leak.

  4. Weigh a few dispensed volumes of distilled water on an analytical balance and compare them with the set volume.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Electronic Pipettes.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Electronic Pipettes and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Electronic Pipettes

AxiTech supplies BOECO Electronic Pipettes together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Electronic Pipettes

Light weight and ergonomic design with comfortable operations help to avoid Repetitive Strain Injuries (RSI)