BOECO Centrifuge C-28A

Reference BOE 01206-13

The non-refrigerated microprocessor-controlled C-28 A is the ideal bench-top centrifuge for performing daily routine tasks in doctors’ laboratories and small hospitals. But because of the wide range of accessories the C-28A can also be used for sample preparation in research and industrial laboratories. The centrifuge has a brushless frequency drive (no carbon brushes). A special locking device allows effortless opening and closing of the lid with just one hand.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 01206-13
Category
Centrifuges
Product range
Centrifuges

Overview

Controls and displays

Safety

The C-28 A conforms to safety regulations such as IEC 61010 or the CE mark and all relevant EC standards and DIN norms and has been manufactured under ISO 9001:2008

Features

  • During centrifugation the actual values of the parameters are indicated
  • Entry of the running parameters via water-protected foil keypad
  • Speed display in RPM x 100, input in steps of 100
  • Time t/min: 1 - 99 min, continous operation
  • Impulse key: For short centrifugation operations
  • Housing and lid of metal finished in a scratch and impact resistant coating
  • Centrifuge chamber of stainless steel
  • Lid locking and holding device
  • See-through glass in the lid
  • Emergency lid lock release
  • Imbalance switch-off
  • Easily exchangeable rotors
  • Automatic rotor recognition

Technical specifications

Net weight
approx 25 kg
Noise Level
< 58 dB (A) (dependent on rotor)
Dimensions in mm
257 (H) x 366 (W) x 430 (D)
Emission / Immunity
EN / IEC 61326-1 class B, FCC class B
Max RPM (speed) / RCF
6.000 rpm / 4.186 RCF
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Centrifuge C-28A

A service visit on the BOECO Centrifuge C-28A covers speed verification with an optical tachometer, inspection of rotors, buckets and adapters for corrosion or fatigue, the lid lock, brake and imbalance detection, and — on refrigerated models — temperature control.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Centrifuges like the BOECO Centrifuge C-28A are normally serviced once a year; rotors are also checked against the manufacturer's cycle or age limit, after which they must be retired.

  • Speed verified with an optical tachometer
  • Rotors, buckets and adapters inspected for corrosion, cracks and wear
  • Lid lock, brake and imbalance detection tested
  • Temperature control verified on refrigerated models; electrical safety checked

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Centrifuge C-28A

When BOECO Centrifuge C-28A fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On centrifuges the frequent faults are imbalance errors, worn motor brushes or bearings, lid-lock failures, and corrosion or damage to rotors and buckets.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Centrifuge C-28A

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Balance the load: opposite positions must hold tubes of equal mass, and every bucket position must be fitted, loaded or not.

  3. Inspect the rotor, buckets and adapters for corrosion, cracks or residue, and check the rotor is seated and locked on the spindle.

  4. Clean spills from the chamber and check the lid seal; note any error code before restarting.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Centrifuge C-28A.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Centrifuge C-28A and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Centrifuge C-28A

AxiTech supplies BOECO Centrifuge C-28A together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Centrifuge C-28A

The non-refrigerated microprocessor-controlled C-28 A is the ideal bench-top centrifuge for performing daily routine tasks in doctors’ laboratories and small hospitals.