BOECO Dry Bath Block Incubator DBI-100, DBI-200 — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Dry Bath Block Incubator DBI-100, DBI-200

Reference BOE 8018000

BOECO DRY BATH BLOCK INCUBATOR DBI-100, DBI-200 are ideal for incubation and activation of cultures, enzyme reactions,blood urea nitrogen eterminations, immunoassays, melting/boiling points and a wide variety of laboratory procedures. A supplied special block extraction tool allows to remove blocks easily.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 8018000
Category
Incubators
Product range
Dry Bath Block incubators

Technical specifications

Model
DBI-100
Timer
1 min - 99,59 hrs
Weight
2,5 kg
Size mm
250x190x130
Power, max
100 W
Block Quantity
1
Display Accuracy
0,1 °C
Temperature control range
RT +5°C - 105°C
Show 3 more specifications
Heating Time (25 to 100°C)
less than 15 min
Temperature Stability @100°C
0,4 °C
Uniformity1)within the block @37°C
0,2 °C
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Dry Bath Block Incubator DBI-100, DBI-200

A service visit on the BOECO Dry Bath Block Incubator DBI-100, DBI-200 covers temperature calibration against a reference thermometer, the circulation pump or rotation drive, the level and over-temperature protection, and the seals, hoses and — on refrigerated units — the cooling circuit.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Baths, circulators and evaporators like the BOECO Dry Bath Block Incubator DBI-100, DBI-200 are normally serviced once a year, with the bath fluid, hoses and seals checked by users at regular intervals.

  • Temperature calibration against a reference thermometer
  • Circulation pump, rotation drive and flow checked
  • Over-temperature and low-level protection tested
  • Seals, hoses, bath fluid and cooling circuit inspected

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Dry Bath Block Incubator DBI-100, DBI-200

When BOECO Dry Bath Block Incubator DBI-100, DBI-200 fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On baths and circulators the frequent faults are scaled or contaminated bath fluid, failing circulation pumps, tripped level or over-temperature protection, worn vacuum seals on evaporators, and cooling circuits that have lost performance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Dry Bath Block Incubator DBI-100, DBI-200

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check the fluid level and condition: low or contaminated fluid trips the level protection and degrades temperature control.

  3. Confirm the safety temperature is set above the working temperature and that hoses and connections are neither kinked nor leaking.

  4. Measure the fluid temperature with an independent thermometer and compare it with the display.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Dry Bath Block Incubator DBI-100, DBI-200.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Dry Bath Block Incubator DBI-100, DBI-200 and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Dry Bath Block Incubator DBI-100, DBI-200

AxiTech supplies BOECO Dry Bath Block Incubator DBI-100, DBI-200 together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Dry Bath Block Incubator DBI-100, DBI-200

BOECO DRY BATH BLOCK INCUBATOR DBI-100, DBI-200 are ideal for incubation and activation of cultures, enzyme reactions,blood urea nitrogen eterminations, immunoassays, melting/boiling points and a wide variety of laboratory procedures.