BOECO Electronic Pipettes Controller, SA Series — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Electronic Pipettes Controller, SA Series

Reference BOE 9600010

Is an engine powered pipetting aid designed for cordless work with glass or plastic pipettes in 0.1 - 200 ml range. Ergonomically shaped and carefully modeled light weight handle, together with its smooth push buttons and conveniently located slide switch it ensures effortless pipetting even during extensive use.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 9600010
Category
Pipettes & Liquid Handling
Product range
Pipette Aids

Features

  • Powerful yet quite pump can fill a 25 ml pipette under 4 seconds
  • Autoclavable pipette cone
  • Double Safety valve and hydrophobic filters provide double protection against fluid penetration
  • Two different speed modes – High, Low along with Gravity drain.
  • Cadmium Free environment friendly NiMH batteries
  • Batteries can be changed very easily by the end user
  • The intelligent charger prevents over charging / heating of batteries
  • Low battery indicator
  • The specially designed desktop stand enables the Pipette Controller to be charged while resting on it
  • The Pipette Controller can hold serological pipette while resting on the desk top stand

Technical specifications

Power
2x1.2 V/1000 mAh rechargeable NiMH batteries
Safety System
Replaceable hydrophobic 0.45 µm and 0.2 µm; PTFE filter, Safety check valve
Volumetric Range
Plastic or Glass pipette from 0.1 ml up to 200 ml
Battery usage duration
Eight hours continuous use
Battery charging duration
2 – 3 hours to charge fully
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Electronic Pipettes Controller, SA Series

A service visit on the BOECO Electronic Pipettes Controller, SA Series covers gravimetric calibration at several volumes following ISO 8655, replacement of seals and O-rings, cleaning and decontamination, and a leak test.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Pipettes like the BOECO Electronic Pipettes Controller, SA Series are typically calibrated every three to twelve months depending on use, following ISO 8655, with a quick gravimetric check by the user in between.

  • Gravimetric calibration at nominal and partial volumes (ISO 8655)
  • Seals, O-rings and piston inspected and replaced when worn
  • Cleaning and decontamination of the lower parts
  • Leak test and tip-ejector check

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Electronic Pipettes Controller, SA Series

When BOECO Electronic Pipettes Controller, SA Series fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

Common pipette faults are leaking seals, contaminated or corroded pistons, damaged tip cones, and volume settings that no longer deliver within tolerance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Electronic Pipettes Controller, SA Series

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Use tips recommended for the pipette and fit them with a firm, straight press: ill-fitting tips are the most common cause of inaccuracy.

  3. Hold the pipette vertically after aspirating — a drop forming at the tip indicates a leak.

  4. Weigh a few dispensed volumes of distilled water on an analytical balance and compare them with the set volume.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Electronic Pipettes Controller, SA Series.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Electronic Pipettes Controller, SA Series and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Electronic Pipettes Controller, SA Series

AxiTech supplies BOECO Electronic Pipettes Controller, SA Series together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Electronic Pipettes Controller, SA Series

1 - 200 ml range. Ergonomically shaped and carefully modeled light weight handle, together with its smooth push buttons and conveniently located slide switch it ensures effortless pipetting even during extensive use.