BOECO Inverted Biological Microscope BIB-100 — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Inverted Biological Microscope BIB-100

Reference BOE 5000.900

Microscope by BOECO Germany: objectives LWD Infinity corrected Plan Achromat Objective 4X/0,1WD 28 mm; illumination 12V 30W Halogen lamp, light intensity adjustable.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 5000.900
Category
Microscopes
Product range
Microscopes

Technical specifications

Body
Innovative stand structure
Power
Inbuilt power supply 100-240V, 50/60Hz
Stage
PlainStage 160 x 250 mm, Glass Insert AuxilaryStage 70 x 180 mm, Attachable Mechanical Ruler
Filter
Diameter 45 mm, blue, green and ground glass
Weight
Net weight 11,0 / 11,7 kgs.
Centering
Centering Telescope 30 mm diam. Telescope Phase Annulus 10X -20X Phase Annulus Plate
Eyepiece
High-point, Extra Wide FieldEyepiece EW 10X /22 mm
Focusing
Coaxial coarse and fine adjustment. Vertical objective movement
Show 7 more specifications
Condenser
ELWD condesner NA 0.3. LWD 72 mm (without condenser 150 mm)
Nosepiece
Quintuple revolving nosepiece
Objectives
LWD Infinity corrected Plan Achromat Objective 4X/0,1WD 28 mm
Illumination
12V 30W Halogen lamp, light intensity adjustable.
Viewing Head
Bino- or Trinocular Head, 30° 360° rotatable, Interpupillary Distance 48 - 75 mm
Supplied with
Dust cover, immersion oil and instruction manual
Optical System
Infinity corrected system, field diameter 22 mm
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Inverted Biological Microscope BIB-100

A service visit on the BOECO Inverted Biological Microscope BIB-100 covers cleaning of the objectives, eyepieces and condenser, alignment of the illumination, and the mechanical stage, focus drive and nosepiece.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Microscopes like the BOECO Inverted Biological Microscope BIB-100 are normally serviced once a year; instruments used in humid rooms benefit from more frequent cleaning to keep fungus off the optics.

  • Objectives, eyepieces, condenser and filters cleaned
  • Illumination and Köhler alignment adjusted
  • Focus mechanism, stage and nosepiece serviced
  • Camera, light source and electrical safety checked where fitted

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Inverted Biological Microscope BIB-100

When BOECO Inverted Biological Microscope BIB-100 fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The usual problems with microscopes are dirty or fungus-affected optics, immersion oil on dry objectives, misaligned illumination, and worn or stiff focus drives.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Inverted Biological Microscope BIB-100

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Clean the eyepieces, objectives and condenser lens with lens tissue and the correct cleaning fluid, and remove immersion oil from the oil objective after every use.

  3. Check the light path: condenser height, field and aperture diaphragms, and that no filter has been left in the wrong position.

  4. If the image is still blurred, try another slide and objective to tell a sample problem from an optical fault.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Inverted Biological Microscope BIB-100.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Inverted Biological Microscope BIB-100 and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Inverted Biological Microscope BIB-100

AxiTech supplies BOECO Inverted Biological Microscope BIB-100 together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Inverted Biological Microscope BIB-100

Key specifications of the BOECO Inverted Biological Microscope BIB-100, according to the manufacturer: objectives LWD Infinity corrected Plan Achromat Objective 4X/0,1WD 28 mm; illumination 12V 30W Halogen lamp, light intensity adjustable.