BOECO Laboratory Binocular Microscope BM-800 — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Laboratory Binocular Microscope BM-800

Reference BOE 8000.550

Microscope by BOECO Germany: objectives BOECO Infinite corrected Plan Achromat Objectives 4x/0.10, 10x/0.25, 40x/0.65 (S), 100x/1.25 (S, Oil); illumination 5W LED lamp, light intensity adjustable.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 8000.550
Category
Microscopes
Product range
Microscopes

Technical specifications

Stage
Large sized double layer mechanical specimen stage. 185 x 142 mm, Moving range 75 x 55 mm
Eyepiece
Larger viewing area with extra wide field eyepiece EWF 10X /22 mm
Focusing
Coaxial coarse and calibrated fine focus control, fine division 0,001 mm, Coarse stroke 37,7mm/rotation fine stroke 0,1mm/rotation, mowing Range 24 mm safety autofocus stop unit.
Condenser
Swing condenser, N.A. 0,9/0,25
Dimension
280 x 358 x 304/416 mm, net weight 10,0/10,4 kgs
Nosepiece
Backward quintuple revolving nosepiece
Objectives
BOECO Infinite corrected Plan Achromat Objectives 4x/0.10, 10x/0.25, 40x/0.65 (S), 100x/1.25 (S, Oil)
Body /power
Modern and ergonomic body made from die-cast aluminium with inbuilt power supply 110-240V, 50/60Hz
Show 5 more specifications
Illumination
5W LED lamp, light intensity adjustable.
Vieving Head
Bin- or Trinocular compensation free head, 30° inclined, 360° rotatable, Interpupillary distance 48 - 75 mm
Supplied with
Dust cover, immersion oil, green filter and instruction manual
Optical System
Infinity corrected system, field diameter 22 mm
Field diaphragm
With aspherical condenser and Köhler Illumination
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Laboratory Binocular Microscope BM-800

A service visit on the BOECO Laboratory Binocular Microscope BM-800 covers cleaning of the objectives, eyepieces and condenser, alignment of the illumination, and the mechanical stage, focus drive and nosepiece.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Microscopes like the BOECO Laboratory Binocular Microscope BM-800 are normally serviced once a year; instruments used in humid rooms benefit from more frequent cleaning to keep fungus off the optics.

  • Objectives, eyepieces, condenser and filters cleaned
  • Illumination and Köhler alignment adjusted
  • Focus mechanism, stage and nosepiece serviced
  • Camera, light source and electrical safety checked where fitted

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Laboratory Binocular Microscope BM-800

When BOECO Laboratory Binocular Microscope BM-800 fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The usual problems with microscopes are dirty or fungus-affected optics, immersion oil on dry objectives, misaligned illumination, and worn or stiff focus drives.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Laboratory Binocular Microscope BM-800

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Clean the eyepieces, objectives and condenser lens with lens tissue and the correct cleaning fluid, and remove immersion oil from the oil objective after every use.

  3. Check the light path: condenser height, field and aperture diaphragms, and that no filter has been left in the wrong position.

  4. If the image is still blurred, try another slide and objective to tell a sample problem from an optical fault.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Laboratory Binocular Microscope BM-800.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Laboratory Binocular Microscope BM-800 and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Laboratory Binocular Microscope BM-800

AxiTech supplies BOECO Laboratory Binocular Microscope BM-800 together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Laboratory Binocular Microscope BM-800

Key specifications of the BOECO Laboratory Binocular Microscope BM-800, according to the manufacturer: objectives BOECO Infinite corrected Plan Achromat Objectives 4x/0.10, 10x/0.25, 40x/0.65 (S), 100x/1.25 (S, Oil); illumination 5W LED lamp, light intensity adjustable.