Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch — main photograph
BOECO GermanyAvailability: Supplied to order

Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

Reference 616

The Android operating system, optimized for the touch operation habits, improves the operating feelings. The integrated design and compact size are ideal to save the space in the crowded laboratories, or as the in-vehicle mobile inspection device. It can be applied to the concentration detection of nucleic acids, proteins, bacterial cell cultures, etc., as well as the absorbance measurement of unknown samples. The variable path length of the N-1C Touch Micro US-Vis Spectrophotometer realizesboth the minimum sample volume pedestal detection as low as 0.5μL, suitable for precious samples, and the detection to the high concentration samples without dilution at all. Including the liquid drop, it builds in the standard cuvette detection module for more use.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
616
Category
Spectrophotometers & Photometers
Product range
Spectrophotometers

Overview

Features Large size colour touch screen Built-in-7-inch high resolution color touch screen for more detection information, all operations can be done on the screen. Two models in one (N-1C Touch) Pedestral Micro volume or cuvette mode, to meet the flexible detection need. The cuvette module has a heating stirrere.

Wide detection range The 0.03 minimum detection path length, combined with a new generation spectrophotometer, increases the maximum detection concentration to 27,500 ng/μl and the lowest detection concentration as low as 0,2 ng/μl Stability for long life Long-life xenon flash lamp of Hamamastu ensures stability of detection and the long life of the instrument. The lifting detection base with sliding bearing structure has high precision, not easy to damage.. Ultra-wide wavelength range With continuous wavelength range as 185-910nm, the instrument can detect various samples through selecting any band. It adapts to a variety of detection requirements with wide range of near infrared wavelength. Accurate path length The stepper motor combined unique double track technology (DPTL), allows the precision of optical path length as 0.001mm, thus to achieve highly repeatability of absorbance detection.) Cuvette detection mode (N-1C Touch) The cuvette detection mode comes with magnetic stirring function. User can set the heating function and stirring speed for dynamic analysis detection. And the user can define different path length, such as 1mm, 2mm, 5mm,10mm. Android operating system The s

Multi-functions Nucleic acid detection Built-in common calculation formula of dsDNA, ssDNA, RNA, Oligo-DNA, Oligo-RNA, can get the concentration and purity of samples automatically. UV visible custom scanning In the full wavelength range, set the detected wavelength through increasing or decreasing wavelength with 1 nm as expected. Nucleic acid fluorescence marker detection Preinstall extinction factor of commonly used fluorescent dyes of dsDNA, ssDNA, RNA, Oligo-DNA, Oligo-RNA. Protein detection Can detect the concentration of protein solution, or detect protein concentration of dye marker. Built-in common detection methods of BCA, Bradford, Lowry, Pierce 660nm. Cell detection Can detect absorbance value at 600nm automatically. Meanwhile, it can detect absorbance value at any band under set wavelength range.

Technical specifications

Code
Description
Power
AC110V-220V 50HZ/60HZ (Power adapter)
Display
7 inch, 1280 x 800 high definition LCD . Internal storage 32GB flash memory
Detector
2048-element liner CCD array
Net Weight
2,3
BOE 8638000
Model N-1 Touch micro UV/Vis Spectrophotometer, with pedestal microvolume mode
BOE 8638100
Model N-1C Touch micro UV/Vis Spectrophotometer, with pedestal microvolume and cuvette mode
Light Source
Xenon flash lamp
Show 17 more specifications
Pathlength (mm)
0.03, 005, 0,1, 0,2, 1,0 auto ranging
Measurement Time
5 Sec.
Limit of Detection
2ng/μl dsDNA
Mini.Sample Amount
(μl) 0.5
Cuvette photometric
0-1,5A (10 mm)
Photometric Accuracy
0-550 (10 mm equivalent)
Wavelength Range (nm)
185-910
PC software requirements
Windows 7:32/64 bit, Windows 8/10 64 bit
Spectral Resolution (nm)
≤1.8(FWHMat Hg 253.7nm)
Wavelength Accuracy (nm)
±1
Measurement Repeatability
0.002 (1mm optical length)
Cuvette Limit of Detection
0.2ng/µl dsDNA, 0,006mg/ml BSA, 0,003 mg//ml LgG
Cuvette Stirring Speed (RPM)
150-900 / 10 Speeds
Limit of Detection Pedestal
2ng/µl ds DNA, 0,006 mg/ml BSA, 0,03 ng/ml lgG
Cuvette Mode Heating Temp.(?)
37±0.5
Data transfer & PC connecting
USB; Wifi
Maximum Concentration Pedestal
27.500 ng/µl ds DNA, 820ml/ml BSA, 400 mg/ml Lg
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

A service visit on the Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch covers the optical path — light source, cell holder and detector — with wavelength and photometric accuracy verified against certified reference standards, plus cleaning and a check of the zero and calibration functions.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Optical instruments like the Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch are usually verified once a year with certified reference standards, and whenever a result is questioned; users should run the manufacturer's check standards between visits.

  • Wavelength and photometric accuracy verified with certified reference standards
  • Light source, detector and cell holder inspected and cleaned
  • Zero, blank and calibration functions checked
  • Firmware, data output and power supply checked

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

When Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The usual faults on optical instruments are dirty or scratched cuvettes and optics, an ageing lamp or LED, stray light, and calibration drift.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Use clean, unscratched cuvettes wiped with a lint-free cloth, filled to the mark and inserted the same way round every time.

  3. Zero or blank the instrument with the sample itself, or with distilled water for a refractometer, before measuring.

  4. Measure a check standard: if it reads correctly, the fault lies with the sample or the reagent rather than the instrument.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

AxiTech supplies Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch

Key specifications of the Boeco Micro UV-VIS Spectrophotometer models N-1 touch & N-1c touch, according to the manufacturer: display 7 inch, 1280 x 800 high definition LCD. Internal storage 32GB flash memory.