BOECO Rotary Evaporator RVO 400 SD — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Rotary Evaporator RVO 400 SD

Reference BOE 8090020

Rotary evaporator by BOECO Germany

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 8090020
Category
Ovens, Furnaces & Water Baths
Product range
Rotary Evaporator

Features

  • With digital display and control
  • Water or oil bath
  • Motorized lif
  • Build in vacuum controler
  • Variable inclination angle of evaporating flask
  • With vertical or diagonal condenser
  • fitted and designed for control and communication by PC

Technical specifications

Net weight
approx 20 kg
Power input
max. 2000 W (excluding vacuum pump)
Power supply
230 V ±10%, 50/60 Hz
Rotation speed
0 - 280 rpm
Bath temperature
max. 100°C for water filling; max. 180°C for oil filling
Digital settings
Temperature, rotations, vacuum
Receiving flasks
100 - 2000 ml
Gradient settings
Temperature, pressure
Show 9 more specifications
Evaporating flasks
20 - 4000 ml
Pressure difference
adjustable 1-500 mbar.
Regulation accuracy
± 1°C up to 100°C; ± 3°C up to 180°C
Pressure measurement
absolute
Switched vacccum pump
output max 650 VA, input max. 2000 VA
Cooler condensation size
1200 sq cm (double sprial)
Pressure units selections
hPa, Torr
Temperature unit selection
°C, °K
Dimensions in mm (WxHxD): Net weight
650 x 900 x 360 (incl. glass)
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Rotary Evaporator RVO 400 SD

A service visit on the BOECO Rotary Evaporator RVO 400 SD covers temperature calibration against a reference thermometer, the circulation pump or rotation drive, the level and over-temperature protection, and the seals, hoses and — on refrigerated units — the cooling circuit.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Baths, circulators and evaporators like the BOECO Rotary Evaporator RVO 400 SD are normally serviced once a year, with the bath fluid, hoses and seals checked by users at regular intervals.

  • Temperature calibration against a reference thermometer
  • Circulation pump, rotation drive and flow checked
  • Over-temperature and low-level protection tested
  • Seals, hoses, bath fluid and cooling circuit inspected

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Rotary Evaporator RVO 400 SD

When BOECO Rotary Evaporator RVO 400 SD fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On baths and circulators the frequent faults are scaled or contaminated bath fluid, failing circulation pumps, tripped level or over-temperature protection, worn vacuum seals on evaporators, and cooling circuits that have lost performance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Rotary Evaporator RVO 400 SD

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check the fluid level and condition: low or contaminated fluid trips the level protection and degrades temperature control.

  3. Confirm the safety temperature is set above the working temperature and that hoses and connections are neither kinked nor leaking.

  4. Measure the fluid temperature with an independent thermometer and compare it with the display.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Rotary Evaporator RVO 400 SD.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Rotary Evaporator RVO 400 SD and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Rotary Evaporator RVO 400 SD

AxiTech supplies BOECO Rotary Evaporator RVO 400 SD together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Rotary Evaporator RVO 400 SD

Plan for the following when installing the BOECO Rotary Evaporator RVO 400 SD: power supply 230 V ±10%, 50/60 Hz; power input max. 2000 W (excluding vacuum pump); dimensions 650 x 900 x 360 (incl. glass); weight approx 20 kg. AxiTech delivers, installs and commissions it, then verifies it against the manufacturer's specification before handover.