BOECO Vacuum Pump R-400 — main photograph
BOECO GermanyAvailability: Supplied to order

BOECO Vacuum Pump R-400

Reference BOE 8840000

are piston-powered, oil-free vacuum pumps, adaptable to many laboratory requirements.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
BOE 8840000
Category
Vacuum Pumps & Aspirators
Product range
Vacuum Pumps

Features

  • quiet and low vibration
  • Compact and light weight
  • Oil free and Maintenance-free

Technical specifications

Pole
4 P
Net weight
6,2 kg
Horse power
1/6 HP
Max. vacuum
670 mm Hg 50 Hz - 60Hz
Noise level
50db
Port thread
5/16 inch
Max flow rate
34 l/min - 37 l/min
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for BOECO Vacuum Pump R-400

A service visit on the BOECO Vacuum Pump R-400 covers the ultimate vacuum and pumping speed, the diaphragms, valves and seals, the controller and sensor, and the hoses, traps and separators.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory vacuum pumps like the BOECO Vacuum Pump R-400 are normally serviced once a year; diaphragms and valves are wear parts, replaced when the pump no longer reaches its ultimate vacuum.

  • Ultimate vacuum and pumping speed measured
  • Diaphragms, valves and seals inspected and replaced when worn
  • Controller, sensor and valves checked
  • Hoses, cold traps and separators inspected

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for BOECO Vacuum Pump R-400

When BOECO Vacuum Pump R-400 fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

Typical faults are worn diaphragms and valves, condensate in the pump head, leaking hoses and connections, and controllers or sensors reading wrongly.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot BOECO Vacuum Pump R-400

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Close the pump inlet and read the vacuum: if the pump reaches its rated value on its own, the leak is in the hoses, the trap or the apparatus.

  3. Check the hoses, clamps and cold trap or separator for leaks and condensate.

  4. Run the pump for a few minutes with the gas ballast open, where fitted, to purge condensed vapours.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for BOECO Vacuum Pump R-400.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using BOECO Vacuum Pump R-400 and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing BOECO Vacuum Pump R-400

AxiTech supplies BOECO Vacuum Pump R-400 together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the BOECO Vacuum Pump R-400

are piston-powered, oil-free vacuum pumps, adaptable to many laboratory requirements.