Air, Gas, Liquid Pt100 Probe — main photograph
Hanna InstrumentsAvailability: Supplied to order

Air, Gas, Liquid Pt100 Probe

Reference HI768L

The HI768L is an air and liquid Pt100 probe designed for use with one of Hanna's Pt100 thermometers. A cable extends 1 m (3.3') from the handle to the meter connection. The rounded tip of the probe allows users to obtain highly accurate temperature readings of air and liquid samples.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI768L
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Product/Accessories, Product/Accessories/Electrodes and probes, Product/Accessories/Electrodes and probes/El

Overview

The HI768L is an air and liquid Pt100 probe designed for use with one of Hanna's Pt100 thermometers. A cable extends 1 m (3.3') from the handle to the meter connection. The rounded tip of the probe allows users to obtain highly accurate temperature readings of air and liquid samples.

Maintenance contract — AxiTech provides planned preventive maintenance for Air, Gas, Liquid Pt100 Probe from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair Air, Gas, Liquid Pt100 Probe on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Measures up to 350°C (622°F)
  • Pt100 sensor
  • AISI 316 stainless steel

Technical specifications

Specifications
SKU
HI768L Accuracy (@25˚C/77˚F) ±0.25°C (±0.5°F) ±3% of reading Recommended Operating Temperature -30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Cable
polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Connection
Pt-100
Body Length
L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Body Material
AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Recommended Use
air, gases Connection Pt-100
Temperature Sensor
yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Accuracy (@25˚C/77˚F)
±0.25°C (±0.5°F) ±3% of reading Recommended Operating Temperature -30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Recommended Operating Temperature
-30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Response Time (90% of final value)
3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Air, Gas, Liquid Pt100 Probe

AxiTech provides preventive maintenance contracts for Air, Gas, Liquid Pt100 Probe. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Air, Gas, Liquid Pt100 Probe

When Air, Gas, Liquid Pt100 Probe fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Air, Gas, Liquid Pt100 Probe

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Air, Gas, Liquid Pt100 Probe.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Air, Gas, Liquid Pt100 Probe and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Air, Gas, Liquid Pt100 Probe

AxiTech supplies Air, Gas, Liquid Pt100 Probe together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Hanna Instruments Air, Gas, Liquid Pt100 Probe

Yes. AxiTech services Air, Gas, Liquid Pt100 Probe, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.