General Purpose Penetration Pt100 Probe — main photograph
Hanna InstrumentsAvailability: Supplied to order

General Purpose Penetration Pt100 Probe

Reference HI768P

The HI768P is a general purpose penetration Pt100 probe designed for use with one of Hanna's Pt100 thermometers. A cable extends 1 m (3.3') from the handle to the meter connection. The sharp, pointed tip of the probe allows users to obtain highly accurate temperature readings of semi-solid and liquid samples.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI768P
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Product/Accessories, Product/Accessories/Electrodes and probes, Product/Accessories/Electrodes and probes/El

Overview

The HI768P is a general purpose penetration Pt100 probe designed for use with one of Hanna's Pt100 thermometers. A cable extends 1 m (3.3') from the handle to the meter connection. The sharp, pointed tip of the probe allows users to obtain highly accurate temperature readings of semi-solid and liquid samples.

Maintenance contract — AxiTech provides planned preventive maintenance for General Purpose Penetration Pt100 Probe from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair General Purpose Penetration Pt100 Probe on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Measures up to 350°C (622°F)
  • Pt100 sensor
  • AISI 316 stainless steel

Technical specifications

Specifications
SKU
HI768P Accuracy (@25˚C/77˚F) ±0.25°C (±0.5°F) ±3% of reading Recommended Operating Temperature -30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Cable
polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Connection
Pt-100
Body Length
L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Body Material
AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Recommended Use
air, gases Connection Pt-100
Temperature Sensor
yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Accuracy (@25˚C/77˚F)
±0.25°C (±0.5°F) ±3% of reading Recommended Operating Temperature -30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Recommended Operating Temperature
-30 to 350°C (-22 to 622°F) Response Time (90% of final value) 3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Response Time (90% of final value)
3 seconds Body Length L 100 mm x dia 3 mm (3.9 x 0.12) Temperature Sensor yes Body Material AISI 316 stainless steel Cable polyurethane (PUR)/straight 1 m (3.3) Recommended Use air, gases Connection Pt-100
Supply and reordering

AxiTech supplies General Purpose Penetration Pt100 Probe as a spare, so a worn part is replaced during the same visit rather than becoming a second call-out.

Ordering General Purpose Penetration Pt100 Probe

Tell us the reference, or the model and serial number of the instrument it belongs to, and we confirm the correct part, its price and its lead time. Parts ordered against a maintenance contract are carried on the visit.

  • Compatibility confirmed against your instrument before despatch
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it belongs to

AxiTech maintains, calibrates and repairs the Hanna Instruments instruments that General Purpose Penetration Pt100 Probe is used with. If you operate one, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about Hanna Instruments General Purpose Penetration Pt100 Probe

Yes. AxiTech supplies General Purpose Penetration Pt100 Probe to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.