Generator Electrode with Diaphragm for HI904

Reference HI900511

The HI900511 is a coulometric generator electrode with diaphragm for the HI904 Karl Fischer titration system. The glass diaphragm separates the anode from the cathode preventing anode-generated iodine from being reduced at the cathode as part of the coulometric reaction. This system is ideal for extremely low water content, nitrogenous compounds and easily reduced samples.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI900511
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Product/Accessories, Product/Titrators

Overview

The HI900511 is a coulometric generator electrode with diaphragm for the HI904 Karl Fischer titration system. The glass diaphragm separates the anode from the cathode preventing anode-generated iodine from being reduced at the cathode as part of the coulometric reaction. This system is ideal for extremely low water content, nitrogenous compounds and easily reduced samples.

Maintenance contract — AxiTech provides planned preventive maintenance for Generator Electrode with Diaphragm for HI904 from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair Generator Electrode with Diaphragm for HI904 on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Glass Body
  • Glass Diaphragm
  • Low Water Content
Supply and reordering

AxiTech supplies Generator Electrode with Diaphragm for HI904 as a spare, so a worn part is replaced during the same visit rather than becoming a second call-out.

Ordering Generator Electrode with Diaphragm for HI904

Tell us the reference, or the model and serial number of the instrument it belongs to, and we confirm the correct part, its price and its lead time. Parts ordered against a maintenance contract are carried on the visit.

  • Compatibility confirmed against your instrument before despatch
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it belongs to

AxiTech maintains, calibrates and repairs the Hanna Instruments equipment that Generator Electrode with Diaphragm for HI904 is used with. If you operate it, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about Hanna Instruments Generator Electrode with Diaphragm for HI904

Yes. AxiTech supplies Generator Electrode with Diaphragm for HI904 to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.