Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) — main photograph
Hanna InstrumentsAvailability: Supplied to order

Lead/Sulfate Half-Cell Ion Selective Electrode (ISE)

Reference HI4012

The HI4012 is a solid state, half-cell ion selective electrode (ISE) for the determination of lead (Pb2+) in solution and indicator for sulfate in titrations. The lead sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The HI4012 is ideal for a variety of applications in the plating industry and environmental monitoring.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI4012
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Industrial/Chemical manufacturing, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Product/Process controllers, Product/Accessories, Product/Access

Overview

The HI4012 is a solid state, half-cell ion selective electrode (ISE) for the determination of lead (Pb2+) in solution and indicator for sulfate in titrations. The lead sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The HI4012 is ideal for a variety of applications in the plating industry and environmental monitoring.

Maintenance contract — AxiTech provides planned preventive maintenance for Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Solid state sensor
  • Detection from 0.21 to 20,700 mg/L Pb2+
  • For use with HI5315 reference half-cell

Technical specifications

Specifications
SKU
HI4012 Type solid-state half cell Measurement Range 0.1M to 1•10-6M 20700 to 0.21 mg/L (ppm) Optimum pH Range 4 to 7 Temperature Range 0 to 80°C Diameter 12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Type
solid-state half cell Measurement Range 0.1M to 1•10-6M 20700 to 0.21 mg/L (ppm) Optimum pH Range 4 to 7 Temperature Range 0 to 80°C Diameter 12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Cable
1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Length
120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Diameter
12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Warranty
6 months
Connection
BNC Warranty 6 months
Body Material
epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Optimum pH Range
4 to 7 Temperature Range 0 to 80°C Diameter 12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Measurement Range
0.1M to 1•10-6M 20700 to 0.21 mg/L (ppm) Optimum pH Range 4 to 7 Temperature Range 0 to 80°C Diameter 12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Temperature Range
0 to 80°C Diameter 12 mm Length 120 mm Body Material epoxy Cable 1 m coaxial Common Applications determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Common Applications
determination of lead ions in plating baths and as an indicator for titrations Connection BNC Warranty 6 months
Supply and reordering

AxiTech supplies Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) as a spare, so a worn part is replaced during the same visit rather than becoming a second call-out.

Ordering Lead/Sulfate Half-Cell Ion Selective Electrode (ISE)

Tell us the reference, or the model and serial number of the instrument it belongs to, and we confirm the correct part, its price and its lead time. Parts ordered against a maintenance contract are carried on the visit.

  • Compatibility confirmed against your instrument before despatch
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it belongs to

AxiTech maintains, calibrates and repairs the Hanna Instruments equipment that Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) is used with. If you operate it, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about Hanna Instruments Lead/Sulfate Half-Cell Ion Selective Electrode (ISE)

Yes. AxiTech supplies Lead/Sulfate Half-Cell Ion Selective Electrode (ISE) to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.