Nickel High Range Reagents (300 tests) — main photograph
Hanna InstrumentsAvailability: Supplied to order

Nickel High Range Reagents (300 tests)

Reference HI93726-03

The HI93726-03 are reagents for the colorimetric determination of nickel. There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI93726-03
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Product/Solutions and reagents, Product/Solutions and reagents/Reagents, Product/Solutions and reagents/Reag

Overview

The HI93726-03 are reagents for the colorimetric determination of nickel. There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

Maintenance contract — AxiTech provides planned preventive maintenance for Nickel High Range Reagents (300 tests) from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair Nickel High Range Reagents (300 tests) on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Nickel High Range Reagents (300 tests)

AxiTech provides preventive maintenance contracts for Nickel High Range Reagents (300 tests). Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Nickel High Range Reagents (300 tests)

When Nickel High Range Reagents (300 tests) fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Nickel High Range Reagents (300 tests)

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Nickel High Range Reagents (300 tests).

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Nickel High Range Reagents (300 tests) and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Nickel High Range Reagents (300 tests)

AxiTech supplies Nickel High Range Reagents (300 tests) together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Hanna Instruments Nickel High Range Reagents (300 tests)

Yes. AxiTech services Nickel High Range Reagents (300 tests), either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.