The HI5313 is a PEI body, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60°C. This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI5313
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Water, Industry/Water/Aquaculture, Industry/Water/Pool and spa water, Industry/Laboratory, Industry/Laboratory/Research, Industry/Laboratory/Education, Industry/Water/Environmental, Parameter

Overview

The HI5313 is a PEI body, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60°C. This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.

Maintenance contract — AxiTech provides planned preventive maintenance for PEI Body Reference Electrode from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair PEI Body Reference Electrode on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Half-Cell Design
  • Durable PEI Body
  • Gel Electrolyte

Technical specifications

Specifications
SKU
HI5313 Description reference electrode Reference single, Ag/AgCl Junction / Flow Rate ceramic Electrolyte gel (KCl 1M + AgCl) Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Cable
1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Reference
single, Ag/AgCl Junction / Flow Rate ceramic Electrolyte gel (KCl 1M + AgCl) Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Connection
4 mm banana
Description
reference electrode Reference single, Ag/AgCl Junction / Flow Rate ceramic Electrolyte gel (KCl 1M + AgCl) Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Electrolyte
gel (KCl 1M + AgCl) Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Max Pressure
0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Body Material
PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Recommended Use
titrations, samples with suspended solids Connection 4 mm banana
Junction / Flow Rate
ceramic Electrolyte gel (KCl 1M + AgCl) Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Recommended Operating Temperature
-5 to 60°C (23 to 140°F) Body Material PEI Cable 1 m (3.3') Recommended Use titrations, samples with suspended solids Connection 4 mm banana
Supply and reordering

AxiTech supplies PEI Body Reference Electrode as a spare, so a worn part is replaced during the same visit rather than becoming a second call-out.

Ordering PEI Body Reference Electrode

Tell us the reference, or the model and serial number of the instrument it belongs to, and we confirm the correct part, its price and its lead time. Parts ordered against a maintenance contract are carried on the visit.

  • Compatibility confirmed against your instrument before despatch
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it belongs to

The Hanna Instruments equipment PEI Body Reference Electrode is used with is what AxiTech maintains, calibrates and repairs. If you operate it, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about Hanna Instruments PEI Body Reference Electrode

Yes. AxiTech supplies PEI Body Reference Electrode to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.