pH Electrode with Micro Bulb and BNC + Pin Connector

Reference HI1083P

The HI1083P is a glass body, single reference junction micro pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters. This electrode features a bulb tip that is only 3 mm in diameter and can be used to measure pH in samples as little as 100 µL. This probe is ideal for 96 well plates and for expensive samples that offer little volume to work with. The HI1083P has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI1083P
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Laboratory, Industry/Food, Industry/Beverage, Parameters/P - Z/pH, Product/Accessories, Product/Accessories/Electrodes and probes, Product/Accessories/Ele

Overview

The HI1083P is a glass body, single reference junction micro pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters. This electrode features a bulb tip that is only 3 mm in diameter and can be used to measure pH in samples as little as 100 µL. This probe is ideal for 96 well plates and for expensive samples that offer little volume to work with. The HI1083P has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell.

Maintenance contract — AxiTech provides planned preventive maintenance for pH Electrode with Micro Bulb and BNC + Pin Connector from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair pH Electrode with Micro Bulb and BNC + Pin Connector on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Open Junction
  • Micro Bulb Tip
  • Viscolene Gel Electrolyte

Technical specifications

Specifications
SKU
HI1083P Description combination pH electrode w/micro bulb for small samples Reference double, Ag/AgCl Junction / Flow Rate open Electrolyte viscolene Max Pressure 0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Cable
coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Range
pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Amplifier
no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Reference
double, Ag/AgCl Junction / Flow Rate open Electrolyte viscolene Max Pressure 0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Connection
BNC + pin* Special Note * For pH meters with CAL Check system
Description
combination pH electrode w/micro bulb for small samples Reference double, Ag/AgCl Junction / Flow Rate open Electrolyte viscolene Max Pressure 0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Electrolyte
viscolene Max Pressure 0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Tip / Shape
spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Max Pressure
0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Special Note
* For pH meters with CAL Check system
Body Material
glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Recommended Use
biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Temperature Sensor
no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Junction / Flow Rate
open Electrolyte viscolene Max Pressure 0.1 bar Range pH: 0 to 13 Recommended Operating Temperature 0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Recommended Operating Temperature
0 to 50°C (32 to 122°F) - GP Tip / Shape spheric (dia: 3 mm) Temperature Sensor no Amplifier no Body Material glass — GP Cable coaxial 1 m (3.3') Recommended Use biotechnology, samples < 100 µL Connection BNC + pin* Special Note * For pH meters with CAL Check system
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for pH Electrode with Micro Bulb and BNC + Pin Connector

AxiTech provides preventive maintenance contracts for pH Electrode with Micro Bulb and BNC + Pin Connector. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for pH Electrode with Micro Bulb and BNC + Pin Connector

When pH Electrode with Micro Bulb and BNC + Pin Connector fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot pH Electrode with Micro Bulb and BNC + Pin Connector

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for pH Electrode with Micro Bulb and BNC + Pin Connector.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using pH Electrode with Micro Bulb and BNC + Pin Connector and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing pH Electrode with Micro Bulb and BNC + Pin Connector

AxiTech supplies pH Electrode with Micro Bulb and BNC + Pin Connector together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Hanna Instruments pH Electrode with Micro Bulb and BNC + Pin Connector

Yes. AxiTech services pH Electrode with Micro Bulb and BNC + Pin Connector, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.