pH/EC/TDS Multiparameter Probe with Quick DIN — main photograph
Hanna InstrumentsAvailability: Supplied to order

pH/EC/TDS Multiparameter Probe with Quick DIN

Reference HI12883

The HI12883 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance free polymer gel electrolyte, and a low temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two graphite sensors for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI12883 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatemnt and boilers and cooling towers. The HI12883 is designed for use with Hanna's HI991300 and HI991301 portable multiparameter meters.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI12883
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Water, Industry/Water/Drinking water, Industry/Laboratory, Industry/Food, Industry/Beverage, Industry/Laboratory/Education, Parameters/P - Z/pH, Product/Accessories, Prod

Overview

The HI12883 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance free polymer gel electrolyte, and a low temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two graphite sensors for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI12883 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatemnt and boilers and cooling towers. The HI12883 is designed for use with Hanna's HI991300 and HI991301 portable multiparameter meters.

Maintenance contract — AxiTech provides planned preventive maintenance for pH/EC/TDS Multiparameter Probe with Quick DIN from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair pH/EC/TDS Multiparameter Probe with Quick DIN on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

Technical specifications

Specifications
SKU
HI12883 Reference single, Ag/AgCl Junction / Flow Rate cloth Electrolyte gel Max Pressure 0.1 bar Range pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Cable
7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Range
pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Amplifier
yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Reference
single, Ag/AgCl Junction / Flow Rate cloth Electrolyte gel Max Pressure 0.1 bar Range pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Connection
Quick connect DIN
Electrolyte
gel Max Pressure 0.1 bar Range pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Tip / Shape
spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Matching Pin
no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Max Pressure
0.1 bar Range pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Body Material
polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Recommended Use
agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Temperature Sensor
yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Junction / Flow Rate
cloth Electrolyte gel Max Pressure 0.1 bar Range pH: 0 to 13/EC Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Recommended Operating Temperature
0 to 50˚C (32 to 122˚F) - LT Tip / Shape spheric (8 mm) Temperature Sensor yes Matching Pin no Amplifier yes Body Material polypropylene Cable 7-pole 1m (3.3') Recommended Use agriculture, boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment Connection Quick connect DIN
Supply and reordering

AxiTech supplies pH/EC/TDS Multiparameter Probe with Quick DIN as a spare, so a worn part is replaced during the same visit rather than becoming a second call-out.

Ordering pH/EC/TDS Multiparameter Probe with Quick DIN

Tell us the reference, or the model and serial number of the instrument it belongs to, and we confirm the correct part, its price and its lead time. Parts ordered against a maintenance contract are carried on the visit.

  • Compatibility confirmed against your instrument before despatch
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it belongs to

AxiTech maintains, calibrates and repairs the Hanna Instruments equipment that pH/EC/TDS Multiparameter Probe with Quick DIN is used with. If you operate it, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about Hanna Instruments pH/EC/TDS Multiparameter Probe with Quick DIN

Yes. AxiTech supplies pH/EC/TDS Multiparameter Probe with Quick DIN to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.