Waterproof Portable EC/TDS/Resistivity/Salinity Meter — main photograph
Hanna InstrumentsAvailability: Supplied to order

Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Reference HI98192

The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
HI98192
Category
pH, Conductivity & Water Analysis
Equipment family
Industry/Industrial, Industry/Industrial/Water treatment, Industry/Water, Industry/Water/Aquaculture, Industry/Water/Wastewater, Industry/Industrial/Plating, Industry/Laboratory, Industry/Laboratory/R

Overview

The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.

Maintenance contract — AxiTech provides planned preventive maintenance for Waterproof Portable EC/TDS/Resistivity/Salinity Meter from Hanna Instruments: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our ph, conductivity & water analysis engineers diagnose and repair Waterproof Portable EC/TDS/Resistivity/Salinity Meter on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Four Ring Probe
  • Quick Connect
  • Ergonomic, One-Handed Operation

Technical specifications

Specifications
Sku
HI98192 Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F) Temperature Resolution 0.1 °C (0.1 °F) Temperature Accuracy @ 25°C / 77°F ±0.2 °C (±0.4 °F) (excluding probe error) Temperature Calibration one or two points EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Weight
400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
EC Range
0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Warranty
2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
TDS Range
0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Dimensions
185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Environment
0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Log Feature
on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Connectivity
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Power Supply
1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
EC Resolution
0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
EC Calibration
automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Salinity Range
% NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
TDS Resolution
0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Power Consumption
approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Recommended Probe
HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Resistivity Range
1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Temperature Range
-20.0 to 120.0 °C (-4.0 to 248.0 °F) Temperature Resolution 0.1 °C (0.1 °F) Temperature Accuracy @ 25°C / 77°F ±0.2 °C (±0.4 °F) (excluding probe error) Temperature Calibration one or two points EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Salinity Resolution
0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Ordering Information
HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Salinity Calibration
max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
TDS Conversion Factor
0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Resistivity Resolution
0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Temperature Resolution
0.1 °C (0.1 °F) Temperature Accuracy @ 25°C / 77°F ±0.2 °C (±0.4 °F) (excluding probe error) Temperature Calibration one or two points EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Temperature Calibration
one or two points EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
EC Accuracy @25°C/77°F
±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Temperature Compensation
NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
TDS Accuracy @ 25°C / 77°F
±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Salinity Accuracy (@25°C/77°F)
±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Resistivity Accuracy (@25°C/77°F)
±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Temperature Accuracy @ 25°C / 77°F
±0.2 °C (±0.4 °F) (excluding probe error) Temperature Calibration one or two points EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) EC Resolution 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm EC Accuracy @25°C/77°F ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) TDS Range 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) TDS Resolution 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L TDS Accuracy @ 25°C / 77°F ±1% of reading (±0.05 ppm or 1 digit whichever greater) TDS Conversion Factor 0.40 to 1.00 Resistivity Range 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) Resistivity Resolution 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* Resistivity Accuracy (@25°C/77°F) ±1% of reading (±10 Ω•cm or 1 digit whichever greater) Salinity Range % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) Salinity Resolution 0.1 % / 0.01 ppt / 0.01 PSU Salinity Accuracy (@25°C/77°F) ±1% of reading Salinity Calibration max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges Temperature Compensation NoTC, Linear, Non Linear ISO/DIS 7888 std Log Feature on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) Connectivity PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Power Supply 1.5V AA batteries (4) Power Consumption approximately 100 hours of continuous use (without backlight), 25 hours with backlight Environment 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. Weight 400 g (14.2 oz) Ordering Information HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. Warranty 2 years Recommended Probe HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9') cable (included)
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Waterproof Portable EC/TDS/Resistivity/Salinity Meter

AxiTech provides preventive maintenance contracts for Waterproof Portable EC/TDS/Resistivity/Salinity Meter. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Waterproof Portable EC/TDS/Resistivity/Salinity Meter

When Waterproof Portable EC/TDS/Resistivity/Salinity Meter fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Waterproof Portable EC/TDS/Resistivity/Salinity Meter.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Waterproof Portable EC/TDS/Resistivity/Salinity Meter and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Waterproof Portable EC/TDS/Resistivity/Salinity Meter

AxiTech supplies Waterproof Portable EC/TDS/Resistivity/Salinity Meter together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Hanna Instruments Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Yes. AxiTech services Waterproof Portable EC/TDS/Resistivity/Salinity Meter, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.