Air Cooled Chiller — main photograph
LabTechAvailability: Supplied to order

Air Cooled Chiller

Reference 2571631

Recirculating chiller by LabTech

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571631
Category
Laboratory Refrigeration & Freezers
Product range
Chillers
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for LabTech Air Cooled Chiller

A service visit on the LabTech Air Cooled Chiller covers temperature calibration against a reference thermometer, the circulation pump or rotation drive, the level and over-temperature protection, and the seals, hoses and — on refrigerated units — the cooling circuit.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Baths, circulators and evaporators like the LabTech Air Cooled Chiller are normally serviced once a year, with the bath fluid, hoses and seals checked by users at regular intervals.

  • Temperature calibration against a reference thermometer
  • Circulation pump, rotation drive and flow checked
  • Over-temperature and low-level protection tested
  • Seals, hoses, bath fluid and cooling circuit inspected

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for LabTech Air Cooled Chiller

When LabTech Air Cooled Chiller fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On baths and circulators the frequent faults are scaled or contaminated bath fluid, failing circulation pumps, tripped level or over-temperature protection, worn vacuum seals on evaporators, and cooling circuits that have lost performance.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot LabTech Air Cooled Chiller

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check the fluid level and condition: low or contaminated fluid trips the level protection and degrades temperature control.

  3. Confirm the safety temperature is set above the working temperature and that hoses and connections are neither kinked nor leaking.

  4. Measure the fluid temperature with an independent thermometer and compare it with the display.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for LabTech Air Cooled Chiller.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using LabTech Air Cooled Chiller and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing LabTech Air Cooled Chiller

AxiTech supplies LabTech Air Cooled Chiller together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the LabTech Air Cooled Chiller

AxiTech supplies the LabTech Air Cooled Chiller (reference 2571631) in Lebanon, with delivery, installation and commissioning. Add it to your request list or send us the reference to receive a quotation — nothing is charged online.