Steam Sterilizer - Benchtop Type, Class B — main photograph
LabTechAvailability: Supplied to order

Steam Sterilizer - Benchtop Type, Class B

Reference 2571512

· Automatic dual lock system· Sterilizer Temp. 110℃ ~135℃

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571512
Category
Autoclaves & Steam Sterilizers
Equipment family
Steam Sterilizers

Overview

Steam Sterilizer - Bench TopClass B Sterilization with Pre & Post Vacuum SystemCatalog Download

Class B sterilization cyclePre vacuum for air removal with 3 stage pulsate steampenetration post vacuum for vacuum drying and HEPAfiltered air coolingAny type of medical device, such as packaged orunpaved solid devices, liquid or hollow instruments

Reinforced and electro-polished stainless steelsquare chamberfor excellent corrosion resistance, long lasting andefficient in space using (Option: STS 316L chamber)

Built- in reservoir with water saving re-circulationsystemprovides for automatic water filling into chamber withlevel sensor

0.2 ㎛ HEPA filter is installedfor clean air to flow into the chamber to protect from aircontamination

Electro polished stainless steel square chamberand silicone gasketwith slopped platform design for excellent sterilizationperformance

Auto dual lock systemAutomatic inter locking with on touch sliding handle forEasy and safe operation

Full automatic operation by pre/ user setprogrammed mode LCD digital controllerwith self diagnostic for error and alarm function

Detachable shelf frame with sturdy wire trayfor easy cleaning and excellent drying performance

1. Automatic over pressure release valve2. Over heating and temperature protector3. Visible and audible alarm for errors4. Automatic dual door locking system5. Door is not opened when the chamber is pressurized6. If the door is not completely closed, it will not start7. Safety pressure release valve&hot water/ steam cooling device8. Low water level sensor and resevoir and alarm lamp9. Electric leakage and over current ciruit breaker

Maintenance contract — AxiTech provides planned preventive maintenance for Steam Sterilizer - Benchtop Type, Class B from LabTech: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory & ivd engineers diagnose and repair Steam Sterilizer - Benchtop Type, Class B on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Steam Sterilizer - Benchtop Type, Class B

AxiTech provides preventive maintenance contracts for Steam Sterilizer - Benchtop Type, Class B. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Steam Sterilizer - Benchtop Type, Class B

When Steam Sterilizer - Benchtop Type, Class B fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Steam Sterilizer - Benchtop Type, Class B

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Steam Sterilizer - Benchtop Type, Class B.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Steam Sterilizer - Benchtop Type, Class B and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Steam Sterilizer - Benchtop Type, Class B

AxiTech supplies Steam Sterilizer - Benchtop Type, Class B together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about LabTech Steam Sterilizer - Benchtop Type, Class B

Yes. AxiTech services Steam Sterilizer - Benchtop Type, Class B, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other LabTech equipment we supply, install and maintain.