AireGard NU-240 Horizontal Laminar Airflow Workstation — main photograph
NuAireAvailability: Supplied to order

AireGard NU-240 Horizontal Laminar Airflow Workstation

Reference NU-240

The benchtop model AireGard™ NU-240 creates HEPA-filtered, ISO Class 5 horizontal laminar flow for sterile but non-hazardous drug compounding in pharmacies or non-hazardous work in research labs.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
NU-240
Category
Biosafety Cabinets & Laminar Flow
Product range
AireGard

Overview

Elevate your workspace with the AireGard™ NU-240, a cutting-edge benchtop model designed for unparalleled adaptability. Whether you choose to install it directly on a bench or opt for an additional base stand, this model fits seamlessly into your laboratory or pharmacy setup. Delivering ISO Class 5 HEPA-filtered horizontal laminar airflow, the NU-240 offers unmatched product protection, making it an invaluable asset for sterile non-hazardous drug compounding for USP 797 compliance or cell culture research requiring product protection. Powered by an advanced ultra-high efficiency motor, it channels air through a top pre-filter and then through a back wall HEPA filter, ensuring ISO Class 5 air purity. Enclosed within robust stainless-steel walls and a durable stainless steel work surface with a PVC core, this model epitomizes both functionality and durability. The intuitive Aeromax™ control system keeps you in command, allowing you to effortlessly monitor workbench performance by visualizing the pressure within the internal airflow plenum. Beyond its core features, the NU-240 is equipped with convenient cord pass-throughs and bright LED lighting. Further customization options include

Optimize your sterile non-hazardous drug compounding preparations with our IV bar option. Boasting 6 hooks and three adjustable height settings, this addition transforms the workstation into an adaptable primary engineering control (PEC) tailored for pharmacy environments. Crafted from stainless steel, it ensures easy cleanability while offering versatility in height placements. Experience unparalleled flexibility and cleanability in one.

Featuring durable stainless steel walls and a work surface fortified with a PVC core, our work zone is designed for cleanability. With the inclusion of two versatile cord-pass throughs, manage your power cords seamlessly, be it for TPN compounding machines or vortex mixers. This meticulous design makes it the premier choice as a primary engineering control for sterile non-hazardous compounding in pharmacies or as a pristine air workbench for microbiology labs.

Experience ease of use like never before with our Aeromax control system. Designed for simplicity, it uses intuitive multicolored lights to display airflow performance. Plus, should workbench performance deviate from the norm, both visual and audible alarms ensure clarity and quick understanding. Simplify your operations with user-friendly electronic controls.

Experience significant energy savings with our ultra-high efficiency DC ECM motor. Not only does it operate with reduced noise, but its optimal power also prolongs HEPA filter life. This means considerable long-term savings, reducing the total cost of ownership for your pharmacy or laboratory. Dive into a future of eco-friendly efficiency and lasting savings.

Features

  • IV Bar with 6 Hooks
  • Stainless Steel Workzone
  • AeroMax Control System
  • Ultra High Efficiency Motor

Technical specifications

Style
Bench top, optional base stand
Diffuser
Metal, non-flammable
Lighting
Standard LED
Motor(s)
1/2 HP DC ECM
Outlet(s)
Optional under worksurface
Sidewalls
Standard Stainless Steel, Optional Polycarbonate
Power Cord
12 ft., 14 GA-3 Wire, 15A
Pre-filter
Top of Unit
Show 41 more specifications
Protection
Product
Rated Amps
6
Plenum Type
HEPEX
Construction
16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Work Surface
Standard Stainless Steel with PVC Core, Optional Nevamar with PVC Core
Supply Filter
99.99% Efficiency on 0.3 microns
Closure Panels
Optional Rear Closure Panels for Seismic Brackets
Control System
AeroMax
Airflow Velocity
90 fpm (0.46 mps)
Airflow Direction
Horizontal
Cord Pass Through
Standard on Right and Left Side Wall
Blower/Lights Amps
5
IV Bar with 6 Hooks
Optional
Net Weight
470 lb (213 kg)
Performance Standard
IEST-RP-CC002-4, ISO-14644-1
Safety Certification
UL, UL-C
HEPA Filter Seal Type
HEPEX Zero Leak Neoprene Seal, Spring-loaded
Work Access Opening(s)
32 (813)
Electrical Configuration
115V60Hz, 230V5060Hz
Heat Rejected
1962 BTU/h
Light Intensity fc (Lux)
90-120 (968-1291)
Seismic Brackets or Studs
Optional Rear or Floor Mount Seismic Brackets
Exterior Depth
32 in (814 mm)
Exterior Width
74 in (1880 mm)
Air Cleanliness (ISO 14644)
ISO-Class-5
Exterior Height
55 3/8 (1406)
Footprint Depth
32 in (814 mm)
Footprint Width
74 in (1880 mm)
Work Area Depth
19 5/8 (498)
Work Area Width
71 7/8 (1826)
Work Area Height
32 in (813 mm)
Est. Shipping Weight
540 lb (245 kg)
Service Valves (3/8-inch NPT)
Optional up to 3 each sidewall
Power Cord Length
12 ft (3.7 m)
Est. Shipping Depth
43 in (1092 mm)
Est. Shipping Width
82 in (2083 mm)
Est. Shipping Height
67 in (1702 mm)
Sound Pressure Level per ISO 4871
Inquire
Airflow Volume at 90
1438 fpm (2443 0.46 mps)
Exterior Height with 30-inch (762 mm) Work Surface Height
81 7/8 (2080) with 27 7/8-in (708mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height
89 7/8 (2282) with 32 7/8-in (835mm) Work Surface Height, Base with LL
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation

A service visit on the NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation covers airflow measurement — inflow and downflow velocities — HEPA filter integrity testing, alarm and interlock checks, and the lighting, UV lamp and electrical safety, following the standard the cabinet is certified to.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Containment and clean-air cabinets like the NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation are tested at installation, after they are moved or have a filter changed, and at least once a year — the interval NSF/ANSI 49 and EN 12469 set for biosafety cabinets and the usual practice for clean benches and fume hoods.

  • Inflow and downflow velocities measured against the rated values
  • HEPA filter integrity (leak) test
  • Airflow alarms, interlocks and sash checked
  • Lighting, UV lamp and electrical safety tested

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation

When NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On containment cabinets the recurring faults are loaded or damaged HEPA filters, airflow that has drifted out of range, failed airflow alarms, and motor or blower problems.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check that the sash or front window is at its working height and that the front grille is not blocked by paper, equipment or forearms.

  3. Read the airflow display or alarm: a low-airflow alarm right after start-up usually means blocked grilles or a loaded filter.

  4. Keep the work zone clear and let the cabinet run for its purge time before starting work; if the alarm persists, stop work and have the airflow measured.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation

AxiTech supplies NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the NuAire AireGard NU-240 Horizontal Laminar Airflow Workstation

The benchtop model AireGard™ NU-240 creates HEPA-filtered, ISO Class 5 horizontal laminar flow for sterile but non-hazardous drug compounding in pharmacies or non-hazardous work in research labs.