AireGard NU-340 Horizontal Laminar Airflow Workstation — main photograph
NuAireAvailability: Supplied to order

AireGard NU-340 Horizontal Laminar Airflow Workstation

Reference NU-340

The console configuration AireGard™ NU-340 creates HEPA-filtered, ISO Class 5 horizontal laminar airflow for sterile but non-hazardous drug compounding in pharmacies or non-hazardous work in research labs.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
NU-340
Category
Biosafety Cabinets & Laminar Flow
Product range
AireGard

Overview

The AireGard™ NU-340 boasts a low-profile console style design, ensuring a seamless fit even in spaces with restricted heights. Its robust stainless steel walls and work surface, enhanced with a PVC core, promise exceptional durability and easy cleanability. HEPA-filtered horizontal laminar airflow ensures ISO Class 5 air purity, making it ideal for sterile drug compounding in pharmacies or meticulous work in research labs. The ultra high efficiency mounted under the work surface draws air through a pre-filter and directs it through a backwall HEPA filter to create an ISO Class 5 level of air cleanliness. The Aeromax™ control system provides real-time airflow monitoring. Standard features include LED lighting and cord pass-throughs, with customizable options like polycarbonate walls, an IV bar, and more for tailored lab or pharmacy setups to meet USP 797 compliance.

Crafted for excellence, the stainless-steel sidewalls paired with a work surface fortified with a PVC core ensure impeccable robustness and ease of cleaning. An ideal primary engineering control for your pharmacy or the perfect clean air workbench for your microbiology laboratory.

With an innovative console design, the NU-340 smartly places its ultra high efficiency motor and air intake at the base, beneath the work surface. This streamlines its profile and enhances efficiency by deploying a reusable foam pre-filter, capturing larger airborne contaminants. This arrangement ensures an extended HEPA filter lifespan, driving down total ownership costs. Plus, with easy front access, pre-filter maintenance is a breeze.

Equipped standard with two cord pass-throughs on each sidewall, our product simplifies your workspace management. Whether using TPN Compounding Machines, Intravenous Workflow Management Systems, or Vacuum Aspiration Systems, effortlessly route and manage your power and data cords within the ISO Class 5 work zone. This intuitive feature promotes organization and ensures a seamless, clutter-free operation, enhancing safety and efficiency.

Our workstation boasts an ultra-high efficiency motor paired with a meticulously designed forward-curved fan located beneath the work surface. In tandem with the HEPEX zero-leak airflow system, this ensures consistent ISO Class 5 laminar airflow throughout the entire work zone. Furthermore, the integration of the HEPEX bag and the attenumount vibration control system not only minimizes vibration transfer, offering an ergonomic setup for technicians, but also provides protection for delicate cell cultures. As an added advantage, the HEPEX bag serves as an effective sound barrier, fostering a quieter and more conducive working environment for all technicians.

Features

  • Stainless Steel Work Zone
  • Pre-Filter Under Work Surface
  • Cable Management
  • Optimal ISO Class 5 Airflow

Technical specifications

Style
Console
Casters
Optional
Diffuser
Metal, non-flammable
Lighting
Standard LED
Motor(s)
1/2 HP DC ECM
Outlet(s)
Optional under worksurface
Sidewalls
Standard Stainless Steel, Optional Polycarbonate
Power Cord
12 ft., 14 GA-3 Wire, 15A
Show 40 more specifications
Pre-filter
Bottom of Unit
Protection
Product
Rated Amps
8
Plenum Type
HEPEX
Construction
16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Work Surface
Standard Stainless Steel with PVC Core, Optional Nevamar with PVC Core
Supply Filter
99.99% Efficiency on 0.3 microns
Closure Panels
Optional Rear Closure Panels for Seismic Brackets
Control System
AeroMax
Airflow Velocity
90 fpm (0.46 mps)
Airflow Direction
Horizontal
Cord Pass Through
Standard on Right and Left Side Wall
Blower/Lights Amps
5
IV Bar with 6 Hooks
Optional
Net Weight
540 lb (245 kg)
Performance Standard
IEST-RP-CC002-4, ISO-14644-1
Safety Certification
UL, UL-C
HEPA Filter Seal Type
HEPEX Zero Leak Neoprene Seal, Spring-loaded
Work Access Opening(s)
32 (813)
Electrical Configuration
115V60Hz, 230V5060Hz
Heat Rejected
1962 BTU/h
Light Intensity fc (Lux)
90-120 (968-1291)
Seismic Brackets or Studs
Optional Rear or Floor Mount Seismic Brackets
Exterior Depth
32 in (814 mm)
Exterior Width
74 in (1880 mm)
Air Cleanliness (ISO 14644)
ISO-Class-5
Exterior Height
76 3/8 (1940) with Leg Levelers
Footprint Depth
32 in (814 mm)
Footprint Width
74 in (1880 mm)
Work Area Depth
19 5/8 (498)
Work Area Width
71 7/8 (1826)
Work Area Height
32 in (813 mm)
Est. Shipping Weight
610 lb (277 kg)
Service Valves (3/8-inch NPT)
Optional up to 3 each sidewall
Power Cord Length
12 ft (3.7 m)
Est. Shipping Depth
43 in (1092 mm)
Est. Shipping Width
84 in (2134 mm)
Est. Shipping Height
88 in (2235 mm)
Sound Pressure Level per ISO 4871
Inquire
Airflow Volume at 90
1438 fpm (2443 0.46 mps)
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation

A service visit on the NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation covers airflow measurement — inflow and downflow velocities — HEPA filter integrity testing, alarm and interlock checks, and the lighting, UV lamp and electrical safety, following the standard the cabinet is certified to.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Containment and clean-air cabinets like the NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation are tested at installation, after they are moved or have a filter changed, and at least once a year — the interval NSF/ANSI 49 and EN 12469 set for biosafety cabinets and the usual practice for clean benches and fume hoods.

  • Inflow and downflow velocities measured against the rated values
  • HEPA filter integrity (leak) test
  • Airflow alarms, interlocks and sash checked
  • Lighting, UV lamp and electrical safety tested

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation

When NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On containment cabinets the recurring faults are loaded or damaged HEPA filters, airflow that has drifted out of range, failed airflow alarms, and motor or blower problems.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check that the sash or front window is at its working height and that the front grille is not blocked by paper, equipment or forearms.

  3. Read the airflow display or alarm: a low-airflow alarm right after start-up usually means blocked grilles or a loaded filter.

  4. Keep the work zone clear and let the cabinet run for its purge time before starting work; if the alarm persists, stop work and have the airflow measured.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation

AxiTech supplies NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the NuAire AireGard NU-340 Horizontal Laminar Airflow Workstation

The console configuration AireGard™ NU-340 creates HEPA-filtered, ISO Class 5 horizontal laminar airflow for sterile but non-hazardous drug compounding in pharmacies or non-hazardous work in research labs.