At a glance

Reference
WL-411-0014
Category
Laboratory Balances

Overview

The supervising part of a mass comparator is a digital module which cooperates with a controller of device’s mechanical components. The automatic mass loader (loading robot) features a basis with self-centering fields, lift and weighing module equipped with a self-centering pan. The digital module and the loading robot are located in mass comparator’s weighing chamber. The lift is handled by a comparator controller. The device is operated by means of digital display which is plugged to mass comparator’s controller.

With this function, the device itself selects the appropriate comparison range depending on the mass of the sample.

The ability of the device to transfer the measurement readability that the mass standard has to other working masses.

for 1 reference standard and 1 test standard.

It reduces the influence of ambient vibrations to a minimum.

included as standard equipment.

Our mass comparators are equipped with a state-of-the-art 5Y weighing terminal, which makes work much easier thanks to its large display and multiple interfaces. The 5Y Weighing Terminal connects directly to: Smartphone or tablet (Hotspot) Spreadsheet (USB-C, Free Link) Printer (Ethernet, Wi-Fi ® , USB-A) Computer (Ethernet, Wi-Fi ® , USB-A) Barcode scanner (USB-A) Any large screen (HDMI) Computer software (RADWAG communication protocol) Keyboard and mouse.

Maintenance contract — AxiTech provides planned preventive maintenance for AKM-2.50.5Y Automatic Mass Comparators from Radwag: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory balances engineers diagnose and repair AKM-2.50.5Y Automatic Mass Comparators on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Smartphone or tablet (Hotspot)
  • Spreadsheet (USB-C, Free Link)
  • Printer (Ethernet, Wi-Fi ® , USB-A)
  • Computer (Ethernet, Wi-Fi ® , USB-A)
  • Barcode scanner (USB-A)
  • Any large screen (HDMI)
  • Computer software (RADWAG communication protocol)
  • Keyboard and mouse.

Technical specifications

Specifications
Display
10″ graphic colour touchscreen
Linearity
±50 mg
Adjustment
external
Net weight
260 kg
Gross weight
380 kg
Power supply
100 – 240 V AC 50/60 Hz
Readability [d]
1 mg
Relative humidity
40% – 60%
Stabilization time
30 s
E1 Calibration Range
20 – 50 kg
E2 Calibration Range
5 – 50 kg
F1 Calibration Range
5 – 50 kg
F2 Calibration Range
5 – 50 kg
M1 Calibration Range
-
M2 Calibration Range
-
Operating temperature
+15 – +30 °C
Maximum capacity [Max]
51 kg
Communication interface
2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi ® , Hotspot
Weighing pan dimensions
ø100 mm
Permissible repeatability
3 mg
Eccentricity (tested load)
0 mg
Weighing device dimensions
1050×650×1150 mm
Electric compensation range
0 g – +51 kg
Controling device dimensions
249×170×72 mm
Standard repeatability [Max]
2 mg
Relative humidity change rate
±5% / 12 h (3% / 4 h)
Packaging dimensions W x D x H
1770×900×1100 mm
Supplementary weights external
-
Supplementary weights internal
-
Operating temperature change rate
±0,5 °C / 12 h (±0,3 °C / 4 h)
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for AKM-2.50.5Y Automatic Mass Comparators

AxiTech provides preventive maintenance contracts for AKM-2.50.5Y Automatic Mass Comparators. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for AKM-2.50.5Y Automatic Mass Comparators

When AKM-2.50.5Y Automatic Mass Comparators fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot AKM-2.50.5Y Automatic Mass Comparators

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for AKM-2.50.5Y Automatic Mass Comparators.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using AKM-2.50.5Y Automatic Mass Comparators and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing AKM-2.50.5Y Automatic Mass Comparators

AxiTech supplies AKM-2.50.5Y Automatic Mass Comparators together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Radwag AKM-2.50.5Y Automatic Mass Comparators

Yes. AxiTech services AKM-2.50.5Y Automatic Mass Comparators, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.