AS 110.R2 PLUS Analytical Balance — main photograph
RadwagAvailability: Supplied to order

AS 110.R2 PLUS Analytical Balance

Reference WL-104-0175

Balance of the AS R2 PLUS series is a standard analytical weighing device of the SYNERGY LAB line . The AS R2 PLUS is exceptional due to a range of modern constructional and system solutions that guarantee reliability, precision and accuracy of measurement, and make everyday operation easy.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
WL-104-0175
Category
Laboratory Balances

Overview

Balance of the AS R2 PLUS series is a standard analytical weighing device of the SYNERGY LAB line . The AS R2 PLUS is exceptional due to a range of modern constructional and system solutions that guarantee reliability, precision and accuracy of measurement, and make everyday operation easy.

The latest AS R2 PLUS analytical balance features spacious weighing chamber, and the open-door clearance facilitates easy access to the weighing pan. With this it is possible to use laboratory glassware of various sizes. New aluminium base is a guarantee for weighing system stability. Dual-CLICK system allows tool-free assembly and disassembly of the weighing chamber, and a special design of guides for weighing chamber panes (no rims) makes keeping the device clean convenient.

Standard AS R2 PLUS balances are equipped with a levelling device located at the front of the weighing chamber, which facilitates level control. Levelling operation is now simplified and easier due to the reduced quantity of adjustable supporting points (2 points).

Balances are equipped with LCD display ensuring clear presentation of the weighing result. Direct access to functions and databases is possible via the following keys: Database – direct access to databases, Function – direct access to basic functions, F1-F4 – programmable function keys and menu navigation keys. AS R2 PLUS analytical balances signal operated working mode, computer connection, weighing and service functions via pictograms. The quantity of displayed weighing units is also expanded. Dedicated status bar enables display of additional messages, e.g. product name, tare value. Real-time mass measurement is presented using bar graph.

Modernized internal adjustment system guarantees accurate indications in extremely unfavourable conditions .

The information system is based on 5 databases, which allows several users to work with several product databases, and the registered weighing results can be subject to further analysis. The data is registered in 5 databases: operators (up to 10 users), products (up to 1000 products), weighings (up to 5000 weighings), tares (up to 100 tares), ALIBI memory (up to 100 000 weighings).

The functionality of AS R2 PLUS balances can be expanded using the following communication interfaces: USB-A, USB-B, RS 232, Wi-Fi ® (option).

Maintenance contract — AxiTech provides planned preventive maintenance for AS 110.R2 PLUS Analytical Balance from Radwag: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory balances engineers diagnose and repair AS 110.R2 PLUS Analytical Balance on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Database – direct access to databases,
  • Function – direct access to basic functions,
  • F1-F4 – programmable function keys and menu navigation keys.
  • operators (up to 10 users),
  • products (up to 1000 products),
  • weighings (up to 5000 weighings),
  • tares (up to 100 tares),
  • ALIBI memory (up to 100 000 weighings).
  • Autotest
  • Dosing
  • Percent Weighing
  • Totalizing
  • Parts counting
  • Peak hold
  • Statistics
  • Checkweighing
  • Under-pan weighing
  • GLP Procedures
  • Animal weighing
  • Density determination

Technical specifications

Specifications
Display
5,3” LCD (backlit)
Linearity
±0,2 mg
Adjustment
internal (automatic)
Net weight
7 kg
OIML Class
I
Tare range
-110 g
Gross weight
9 kg
Minimum load
10 mg
Leveling system
manual
Readability [d]
0,1 mg
Protection class
IP 43
Relative humidity
40% – 80%
Stabilization time
2 s
Delivery components
Balance, weighing pan, weighing pan shield, centring ring, bottom cover, power supply.
Minimum weight (USP)
120 mg
Operating temperature
+10 – +40 °C
Verification unit [e]
1 mg
Maximum capacity [Max]
110 g
Power consumption max.
3 W
Weighing chamber doors
manual
Communication interface
2×RS232¹, 2×USB-A (interchangeable), USB-B, Wi-Fi ® (option)
Weighing pan dimensions
ø100 mm
Minimum weight (U=1%, k=2)
12 mg
Standard repeatability [Max]
0,08 mg
Packaging dimensions W x D x H
490×400×520 mm
Permissible repeatability [Max]
0,1 mg
Standard repeatability [5% Max]
0,06 mg
Permissible repeatability [5% Max]
0,09 mg
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for AS 110.R2 PLUS Analytical Balance

AxiTech provides preventive maintenance contracts for AS 110.R2 PLUS Analytical Balance. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for AS 110.R2 PLUS Analytical Balance

When AS 110.R2 PLUS Analytical Balance fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot AS 110.R2 PLUS Analytical Balance

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for AS 110.R2 PLUS Analytical Balance.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using AS 110.R2 PLUS Analytical Balance and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing AS 110.R2 PLUS Analytical Balance

AxiTech supplies AS 110.R2 PLUS Analytical Balance together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Radwag AS 110.R2 PLUS Analytical Balance

Yes. AxiTech services AS 110.R2 PLUS Analytical Balance, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.