C315.60/150.OW-1 Personal Scale — main photograph
RadwagAvailability: Supplied to order

C315.60/150.OW-1 Personal Scale

Reference WM-004-1030

The C315.60/150.OW-1 Personal Scale is designed for weighing primarily patients in healthcare institutions, but not only – also students in schools or athletes in sports centres. The height of the person weighed (up to 2 m) can be measured using the height-meter. The C315.60/150.OW-1 Personal Scales have a terminal installed on the pillar.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
WM-004-1030
Category
Patient Weighing Scales

Overview

The C315.60/150.OW-1 Personal Scale is designed for weighing primarily patients in healthcare institutions, but not only – also students in schools or athletes in sports centres. The height of the person weighed (up to 2 m) can be measured using the height-meter. The C315.60/150.OW-1 Personal Scales have a terminal installed on the pillar.

The C315.60/150.OW-1 Personal Scale enables the BMI (Body Mass Index ), or Quetelet index, to be set for adults over 1 metre tall. The BMI is determined by entering the height value read from the height-meter into the scale. Assessing BMI is very important not only for those on a diet, but also for those with type II diabetes or atherosclerosis or at risk of a heart attack.

Maintenance contract — AxiTech provides planned preventive maintenance for C315.60/150.OW-1 Personal Scale from Radwag: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our patient weighing scales engineers diagnose and repair C315.60/150.OW-1 Personal Scale on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Internal battery
  • Peak hold
  • GLP Procedures
  • ALIBI Memory
  • BMI

Technical specifications

Specifications
Display
4,3” LCD (backlit)
Net weight
8,5 kg
OIML Class
III
Tare range
-150 kg
Gross weight
10 kg
Power supply
100 – 240 V AC 50/60 Hz and battery
Readability [d]
20 / 50 g
Relative humidity
10% – 85% RH no condensation
Operating temperature
0 – +40 °C
Maximum capacity [Max]
60 / 150 kg
Power consumption max.
5 W
Communication interface
RS232
Operation time on batteries
up to 8 h
Packaging dimensions W x D x H
1150×400×110 mm
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for C315.60/150.OW-1 Personal Scale

AxiTech provides preventive maintenance contracts for C315.60/150.OW-1 Personal Scale. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for C315.60/150.OW-1 Personal Scale

When C315.60/150.OW-1 Personal Scale fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot C315.60/150.OW-1 Personal Scale

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for C315.60/150.OW-1 Personal Scale.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using C315.60/150.OW-1 Personal Scale and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing C315.60/150.OW-1 Personal Scale

AxiTech supplies C315.60/150.OW-1 Personal Scale together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Radwag C315.60/150.OW-1 Personal Scale

Yes. AxiTech services C315.60/150.OW-1 Personal Scale, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.