PS 200/2000.5Y Precision Balance — main photograph
RadwagAvailability: Supplied to order

PS 200/2000.5Y Precision Balance

Reference WL-220-0418

Are you looking for a balance that not only weighs accurately, but also performs a digital audit, responds to your voice and sends light messages? If so, find out what the PS 5Y balances have to offer:

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
WL-220-0418
Category
Laboratory Balances

Overview

Are you looking for a balance that not only weighs accurately, but also performs a digital audit, responds to your voice and sends light messages? If so, find out what the PS 5Y balances have to offer:

Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity.

The light colour will tell you about status, process results, procedures, or alerts.

Prepared to display what you need most at any given moment.

Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11 . – Full data security – Electronic signatures – Validations – Electronic records – Audit trails

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds .

Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement.

Maintenance contract — AxiTech provides planned preventive maintenance for PS 200/2000.5Y Precision Balance from Radwag: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory balances engineers diagnose and repair PS 200/2000.5Y Precision Balance on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Autotest
  • Dosing
  • Percent Weighing
  • Parts counting
  • Peak hold
  • Formulation
  • Statistics
  • Checkweighing
  • IR sensors
  • Under-pan weighing
  • GLP Procedures
  • Animal weighing
  • Pipettes Calibration
  • Air density correction
  • Density determination
  • Differential weighing
  • Ambient conditions monitoring
  • Statistical Quality Control
  • Packaged Goods Control
  • ALIBI Memory
  • Wi-Fi ®

Technical specifications

Specifications
Display
10″ graphic colour touchscreen
Linearity
±2 / 20 mg
Adjustment
internal (automatic)
Net weight
3,99 kg
OIML Class
II
Tare range
-2000 g
Gross weight
5,5 kg
Minimum load
20 mg
Power supply
Adapter: 100 – 240V AC 50/60Hz 1A Max; 15V DC 2,4A Balance: 12 – 15V DC 1,4A max; 9 – 17W*
Leveling system
semi-automatic – LevelSENSING
Readability [d]
1 / 10 mg
Protection class
IP 43
Database capacity
7
Relative humidity
40% – 80%
Stabilization time
2 / 1,5 s
Delivery components
Balance, weighing pan, grounding bumper ×1, bumper ×3, fabric dust cover, power supply
Minimum weight (USP)
1 g
Touch free operation
2 IR Sensors
Operating temperature
+10 – +40 °C
Verification unit [e]
10 / 100 mg
Maximum capacity [Max]
200 / 2000 g
Communication interface
2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi ® , Hotspot
Weighing pan dimensions
128×128 mm
Minimum weight (U=1%, k=2)
0,1 g
Standard repeatability [Max]
1 / 10 mg
Packaging dimensions W x D x H
600×400×550 mm
Standard repeatability [5% Max]
0,5 / 5 mg
Ambient conditions monitoring (option)
THBR 2.0 System, THBR BOX, THB P, THB W, THB S
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for PS 200/2000.5Y Precision Balance

AxiTech provides preventive maintenance contracts for PS 200/2000.5Y Precision Balance. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for PS 200/2000.5Y Precision Balance

When PS 200/2000.5Y Precision Balance fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot PS 200/2000.5Y Precision Balance

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for PS 200/2000.5Y Precision Balance.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using PS 200/2000.5Y Precision Balance and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing PS 200/2000.5Y Precision Balance

AxiTech supplies PS 200/2000.5Y Precision Balance together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Radwag PS 200/2000.5Y Precision Balance

Yes. AxiTech services PS 200/2000.5Y Precision Balance, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.