WLC 10.X7 Precision Balance — main photograph
RadwagAvailability: Supplied to order

WLC 10.X7 Precision Balance

Reference WL-227-0010

WLC X7 Precision Balances are high-tech yet easy-to-use weighing devices at a very good price. They have a clear menu, which the user will enjoy working on via a 7-inch touchscreen display .

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
WL-227-0010
Category
Laboratory Balances

Overview

WLC X7 Precision Balances are high-tech yet easy-to-use weighing devices at a very good price. They have a clear menu, which the user will enjoy working on via a 7-inch touchscreen display .

Features and functionalities such as: 7-inch color touchscreen display Screen personalization through widgets Multilingual interactive menus Touchless operation sensors Compliance with GLP and GMP requirements Dynamic sample mass control ( bargraph ) Statistics, recipes, reports and printouts Unlimited communication possibilities ALIBI memory with measurement recording Extensive databases Highest operating comfort Internal/ external adjustment provide the user with the highest readability and maximum operating comfort.

In WLC X7 Precision Balances the information system is based on 9 databases which allow several users to work with database storing several products. The registered weighing results can be subject to further analysis. The data is registered in 9 databases: Products (5 000 products) Users (100 users) Packaging (100 packaging types) Customers (1 000 customers) Formulations (100 formulations) Formulations reports (500 reports) Ambient Conditions (10 000 records) Weighings (50 000 records) ALIBI memory (512 000 records).

Maintenance contract — AxiTech provides planned preventive maintenance for WLC 10.X7 Precision Balance from Radwag: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory balances engineers diagnose and repair WLC 10.X7 Precision Balance on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • 7-inch color touchscreen display
  • Screen personalization through widgets
  • Multilingual interactive menus
  • Touchless operation sensors
  • Compliance with GLP and GMP requirements
  • Dynamic sample mass control ( bargraph )
  • Statistics, recipes, reports and printouts
  • Unlimited communication possibilities
  • ALIBI memory with measurement recording
  • Extensive databases
  • Highest operating comfort
  • Internal/ external adjustment
  • Products (5 000 products)
  • Users (100 users)
  • Packaging (100 packaging types)
  • Customers (1 000 customers)
  • Formulations (100 formulations)
  • Formulations reports (500 reports)
  • Ambient Conditions (10 000 records)
  • Weighings (50 000 records)
  • ALIBI memory (512 000 records).
  • Autotest
  • Dosing
  • Plus/Minus Control
  • Percent Weighing
  • Parts counting
  • Peak hold
  • Formulation
  • Statistics
  • Checkweighing
  • IR sensors
  • Under-pan weighing
  • GLP Procedures
  • Animal weighing
  • Density determination
  • Ambient conditions monitoring
  • Replaceable unit
  • Statistical Quality Control
  • ALIBI Memory
  • Mass for titrator
  • Wi-Fi ®

Technical specifications

Specifications
Display
7″ graphic colour touchscreen
Linearity
±0,3 g
Adjustment
external
Net weight
2,2 kg
Tare range
-10 kg
Gross weight
3,8 kg
Power supply
Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A Balance: 10 – 15VDC 0,6A max
Repeatability
0,08 g
Leveling system
manual
Readability [d]
0,1 g
Protection class
IP 43
Database capacity
Products, Users, Packaging, Customers, Formulations, Formulations reports, Ambient Conditions, Weighings, Alibi memory
Stabilization time
2 s
Operating temperature
+10 – +40 °C
Verification unit [e]
-
Maximum capacity [Max]
10 kg
Communication interface
2×RS232¹, USB-A, USB-B, Ethernet, Wi-Fi ®
Weighing pan dimensions
195×195 mm
Packaging dimensions W x D x H
475×380×345 mm
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for WLC 10.X7 Precision Balance

AxiTech provides preventive maintenance contracts for WLC 10.X7 Precision Balance. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for WLC 10.X7 Precision Balance

When WLC 10.X7 Precision Balance fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot WLC 10.X7 Precision Balance

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for WLC 10.X7 Precision Balance.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using WLC 10.X7 Precision Balance and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing WLC 10.X7 Precision Balance

AxiTech supplies WLC 10.X7 Precision Balance together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about Radwag WLC 10.X7 Precision Balance

Yes. AxiTech services WLC 10.X7 Precision Balance, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.