HB digital — main photograph
IKAAvailability: Supplied to order

HB digital

Reference 0020016334

HB digital laboratory stirrer from IKA — supplied, installed and commissioned by AxiTech, with preventive maintenance, calibration, troubleshooting, repair and genuine spare parts.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0020016334
Category
Shakers, Stirrers & Mixers

Overview

HB digital Compact and ergonomic heating safety bath for all tempering media. 4 l bath volume Max. media temperature: 180 °C Ergonomic handles Key button to lock heating bath temperature Clear, black-and-white display Safety operating modes A, B, C Permanent set-point/ actual temperature display USB interface Scope of delivery HB digital USB Cable - USB A to Micro-B, 2 m

Maintenance contract — AxiTech provides planned preventive maintenance for HB digital from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair HB digital on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • 4 l bath volume
  • Max. media temperature: 180 °C
  • Ergonomic handles
  • Key button to lock heating bath temperature
  • Clear, black-and-white display
  • Safety operating modes A, B, C
  • Permanent set-point/ actual temperature display
  • USB interface
  • HB digital
  • USB Cable - USB A to Micro-B, 2 m

Technical specifications

Specifications
Weight
3.9 kg
Voltage
220 - 240 V
Frequency
50/60 Hz
Heat output
1400 W
Power input
1450 W
Heat control
Turning knob
Inner height
130 mm
Outer height
190 mm
USB interface
Micro-USB
Inner diameter
225 mm
Outer diameter
257 mm
Filling point min.
60 mm
Filling volume max.
4 l
Power input standby
3 W
Temperature display
LCD
Fixed safety circuit
190 °C
Dimensions (W x H x D)
330 x 190 x 325 mm
Adjustable safety circuit
50 - 190 °C
Heating temperature range
room temp. - 180 °C
Set temperature resolution
1 K
Permissible relative humidity
80 %
Material in contact with medium
stainless steel 1.4404
Permissible ambient temperature
5 - 40 °C
Class designation acc. DIN 12876
II
Protection class according to DIN EN 60529
IP 21
Absolute deviation/mean (3l water / 90 °C)
±2 K
Controller oscillation (3 l water / 90 °C)
±1 K
Controller oscillation (3l Silicone oil / 50mPas / 150°C)
±2 K
Absolute deviation/mean (3 l Silicone oil / 50mPas/ 150°C)
±4 K
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for HB digital

AxiTech provides preventive maintenance contracts for HB digital. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for HB digital

When HB digital fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot HB digital

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for HB digital.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using HB digital and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing HB digital

AxiTech supplies HB digital together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA HB digital

Yes. AxiTech services HB digital, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.