ICC 100 lite eco 8 — main photograph
IKAAvailability: Supplied to order

ICC 100 lite eco 8

Reference 0010013176

ICC 100 lite eco 8 laboratory stirrer from IKA. AxiTech covers the full lifecycle: installation and commissioning, planned preventive maintenance, periodic calibration, on-site troubleshooting, workshop repair and spare parts supply.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010013176
Category
Shakers, Stirrers & Mixers

Overview

ICC 100 lite eco 8 The compact immersion circulators of the lite series are powerful and of high quality, with a focus on essential basic functions, excellent performance and efficient operation. ICC 100 lite is suitable for tempering liquids up to 100 °C and internal circulation. To make configuration of your temperature control system as convenient as possible, IKA offers “ready-to-connect” packages with all the necessary accessories. Package includes: ICC 100 lite Compact immersion circulator IB 8 eco Plastic bath (size S) BS.ICC lite Bath bridge, small Max. temperature in the plastic bath (eco): 100 °C (water only) Technical data relates to the temperature control instrument included in the package.

Maintenance contract — AxiTech provides planned preventive maintenance for ICC 100 lite eco 8 from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair ICC 100 lite eco 8 on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Technical specifications

Specifications
Weight
4.2 kg
Voltage
230 V
Frequency
50/60 Hz
Heat output
2000 W
Power input
2100 W
USB interface
USB-B
Appliance type
Compact immersion circulators
Bath depth min.
150 mm
RS 232 interface
yes
Appliance fastener
clamp
Calibration option
yes
Display resolution
0.1 K
Permissible ON time
100 %
Temperature control
PID
Temperature display
yes
Working temperature
room temp. - 100 °C
Sub level protection
yes
Dimensions (W x H x D)
135 x 303 x 180 mm
Warning function optical
yes
Adjustable safety circuit
0 - 110 °C
Safety temperature sensor
PT1000
Warning function acoustic
yes
Safety temperature display
LED
Set temperature resolution
0.1 K
Working temperature sensor
PT1000
Working temperature display
LED
Permissible relative humidity
80 %
Permissible ambient temperature
5 - 40 °C
Temperature stability DIN 12876
±0.05 K
Class designation acc. DIN 12876
III
Identification according to DIN 12876
FL
Technical data complies with the standard
DIN 12876
Protection class according to DIN EN 60529
IP 21
Operating temperature min. (with external cooling)
-25 °C
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for ICC 100 lite eco 8

AxiTech provides preventive maintenance contracts for ICC 100 lite eco 8. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for ICC 100 lite eco 8

When ICC 100 lite eco 8 fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot ICC 100 lite eco 8

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for ICC 100 lite eco 8.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using ICC 100 lite eco 8 and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing ICC 100 lite eco 8

AxiTech supplies ICC 100 lite eco 8 together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA ICC 100 lite eco 8

Yes. AxiTech services ICC 100 lite eco 8, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.