IKA G-L — main photograph
IKAAvailability: Supplied to order

IKA G-L

Reference 0030000774

IKA G-L laboratory stirrer from IKA. AxiTech covers the full lifecycle: installation and commissioning, planned preventive maintenance, periodic calibration, on-site troubleshooting, workshop repair and spare parts supply.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0030000774
Category
Shakers, Stirrers & Mixers

Overview

IKA G-L Separating substances at medium rotational speeds: IKA G-L is the ideal midi centrifuge for all types of separation processes such as those found in molecular biology. It can be used with standard 1.5/2 ml vessels, as well as with PCR strips (optional rotor needed). The cover opens automatically at the press of a button. Safe use The centrifuge is fitted with a metal cover and does not start until it is firmly closed. State-of-the-art display The completely intuitive navigation is carried out through a membrane keypad. This allows an easy setting of speed, rotational speed or programmes. Powerful motor With a rotational speed of up to 15,700 rpm, the centrifuge is fitted with a high-performance motor. Broad scope of delivery Metal rotor and cover for 12 vessels, with a capacity of 1.5/2 ml, are already included in the scope of delivery. Scope of delivery IKA G-L Metal rotor set 12 x 1.5/2.0 ml Screwdriver for opening the lid in emergency USB A-B Cable

Maintenance contract — AxiTech provides planned preventive maintenance for IKA G-L from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair IKA G-L on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • IKA G-L
  • Metal rotor set 12 x 1.5/2.0 ml
  • Screwdriver for opening the lid in emergency
  • USB A-B Cable

Technical specifications

Specifications
Timer
yes
Weight
3.9 kg
Voltage
220 - 230 V
Capacity
12 x 1.5/2.0 ml
Frequency
50/60 Hz
Quick stop
yes
Noise level
55 dB(A)
Power input
92 W
Speed range
800 - 15700 rpm
Cover opening
automatic
Timer display
7 segment LED
USB interface
USB-B
Rotor exchange
without tool
Speed deviation
2.5 %
Pemitted density
1.2 kg/dm3
Protective cover
yes
Unbalance sensor
yes
Motor rating input
65 W
Kinetic energy max.
940 Nm
Power input standby
3 W
Dimensions (W x H x D)
200 x 140 x 280 mm
Setting accuracy speed
±100 rpm
Display changeable rpm rcf
yes
Permissible relative humidity
80 %
Permissible ambient temperature
+5 - +40 °C
Shortest start up time to max. speed
17 s
RCF (relative centrifugal force) max.
16500 G
Shortest breaking time from max. speed
18 s
Protection class according to DIN EN 60529
IP 20
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for IKA G-L

AxiTech provides preventive maintenance contracts for IKA G-L. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for IKA G-L

When IKA G-L fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot IKA G-L

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for IKA G-L.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using IKA G-L and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing IKA G-L

AxiTech supplies IKA G-L together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA IKA G-L

Yes. AxiTech services IKA G-L, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.