IKA MultiDrive basic — main photograph
IKAAvailability: Supplied to order

IKA MultiDrive basic

Reference 0025002638

IKA MultiDrive basic laboratory stirrer from IKA — AxiTech supports hospitals, clinics and laboratories with sales, installation, maintenance contracts, calibration, repair and spare parts for this equipment.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0025002638
Category
Shakers, Stirrers & Mixers

Overview

IKA MultiDrive basic Regardless of whether samples are hard, soft or fibrous – the IKA MultiDrive crusher can perform a wide range of crushing tasks involving coarse and fine crushing, thanks to the variety of vessels available (vessels not included in delivery). With MultiDrive basic it is possible to mix or grind. There is a USB interface available for easy actuation and documentation. High performance Excellent crushing performance is guaranteed by a combination of variable rotational speeds, ranging from 3000 rpm to 20 000 rpm, and a 1000 Watt output. Interval operation The option of interval programming is simple to activate at the press of a button. Interval operation is an asset during the coarse crushing of hard samples or for extra thorough blending. Integrated cooling A cooling system is integrated in the milling chambers (MI, available as accessory), which allows indirect heat dissipation. Thus, coolant and sample remain separate. Variety of vessels (accessory) MultiDrive provides the right vessel for each grinding task. For MultiDrive basic, milling chambers (MI) for dry grinding and blending vessels (BL) for wet grinding are available. Vessels are not part of the scope

Maintenance contract — AxiTech provides planned preventive maintenance for IKA MultiDrive basic from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair IKA MultiDrive basic on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • IKA MultiDrive basic
  • Socket wrench
  • Disassembly tool 1
  • Disassembly tool 2
  • Cleaning brush
  • USB Cable - USB A to Micro-B, 2 m

Technical specifications

Specifications
Weight
8.5 kg
Display
7 segment LED
Voltage
220 - 240 V
Frequency
50/60 Hz
Power input
1000 W
Speed range
3000 - 20000 rpm
Process type
batch
Power ON time
5 min
USB interface
Micro-USB
Power OFF time
10 min
Motor principle
Brushless DC
Speed deviation
±5 %
Vessels detection
yes
Motor rating input
1000 W
Motor rating output
800 W
Operating principle
cutting/impact/blending/dispersing
Dimensions (W x H x D)
300 x 350 x 250 mm
Permissible relative humidity
80 %
Permissible ambient temperature
5 - 40 °C
Protection class according to DIN EN 60529
IP 31
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for IKA MultiDrive basic

AxiTech provides preventive maintenance contracts for IKA MultiDrive basic. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for IKA MultiDrive basic

When IKA MultiDrive basic fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot IKA MultiDrive basic

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for IKA MultiDrive basic.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using IKA MultiDrive basic and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing IKA MultiDrive basic

AxiTech supplies IKA MultiDrive basic together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA IKA MultiDrive basic

Yes. AxiTech services IKA MultiDrive basic, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.