INC 125 FS digital (SP25) Incubator shaker — main photograph
IKAAvailability: Supplied to order

INC 125 FS digital (SP25) Incubator shaker

Reference 0020117230

INC 125 FS digital (SP25) Incubator shaker laboratory stirrer from IKA — AxiTech supports hospitals, clinics and laboratories with sales, installation, maintenance contracts, calibration, repair and spare parts for this equipment.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0020117230
Category
Shakers, Stirrers & Mixers

Overview

INC 125 FS digital (SP25) Incubator shaker INC 125 FS digital is the first incubator shaker with a patented removable shaker platform. Without the platform, the unit can be used like a normal incubator. The large inner chamber with a volume of 125 liters offers space for up to 6 grid shelves (without shaker platform). Thanks to high temperature stability and a uniform shaking motion that improves oxygenation, the incubator shaker is the perfect solution for cell cultivation and other microbiological applications. Patented removable shaker platform • High shaking speed up to 300 rpm • Shaking stroke: 25 mm (optional: 20 mm) for optimum oxygen input • The shaker platform can be pulled out halfway (with line indicator) for comfortable and tilt-proof loading. • The threaded grid on the platform allows the mounting of fixing clips or STICKMAX adhesive mat for different vessels and sizes • Automatic detection of the shaker platform allows the temperature to be automatically adjusted in decontamination mode (100 or 120°C) • When the door is opened, the shaking function stops automatically • Shaking and temperature control function can be used independently of each other Easy to clean • Si

Maintenance contract — AxiTech provides planned preventive maintenance for INC 125 FS digital (SP25) Incubator shaker from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair INC 125 FS digital (SP25) Incubator shaker on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • INC 125 FS digital
  • shaker platform SP25
  • IO T 2.10 Wire grid tray, chrome plated (2 pcs.)
  • Tilt protection (2 pcs.)
  • USB A-B Cable
  • Calibration certificate at 37°C

Technical specifications

Specifications
Fuse
2x T5.0A 250V
Weight
70 kg
Display
LCD
Voltage
200 - 240 V
Frequency
50/60 Hz
Heat output
750 W
Power input
850 W
Speed range
10 - 300 rpm
USB interface
USB-B
Shaking stroke
25 mm
Door with window
yes
Power input max.
850 W
Time setting max.
100 d
Power input standby
2 W
Temperature display
yes
Working temperature
room temp. +8 - 80 °C
Number of trays max.
6
Dimensions (W x H x D)
700 x 720 x 635 mm
Load for one tray max.
20 kg
Set up plate dimensions
340 x 480 mm
Power consumption at 37°C
85 Wh/h
Temperature sensor control
PT 100 4 wire
Total volume inner chamber
125 l
Operating area inner chamber
550 x 550 x 415 mm
Permissible relative humidity
80 %
Permissible ambient temperature
15 - 32 °C
Adjustment and display resolution
0.1 K
Temperature stability (37°C @22°C)
±0.1 K
Set point limiter with safety shutdown
yes
Temperature homogeneity (37°C @22°C)
±0.2 K
Temperature heat up time (37°C @22°C)
12 min
Temperature door recovery (37°C @22°C)
2 min
Cleaning thermal decontamination (120°C)
yes
Protection class according to DIN EN 60529
IP 20
Thermal safety devices according DIN 12880
TB class 1
Permissible shaking weight (incl. attachment)
7.5 kg
Thermal decontamination with SP20/25 (100°C)
yes
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for INC 125 FS digital (SP25) Incubator shaker

AxiTech provides preventive maintenance contracts for INC 125 FS digital (SP25) Incubator shaker. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for INC 125 FS digital (SP25) Incubator shaker

When INC 125 FS digital (SP25) Incubator shaker fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot INC 125 FS digital (SP25) Incubator shaker

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for INC 125 FS digital (SP25) Incubator shaker.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using INC 125 FS digital (SP25) Incubator shaker and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing INC 125 FS digital (SP25) Incubator shaker

AxiTech supplies INC 125 FS digital (SP25) Incubator shaker together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA INC 125 FS digital (SP25) Incubator shaker

Yes. AxiTech services INC 125 FS digital (SP25) Incubator shaker, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.