MATRIX Orbital Delta Plus — main photograph
IKAAvailability: Supplied to order

MATRIX Orbital Delta Plus

Reference 0010006853

MATRIX Orbital Delta Plus laboratory stirrer from IKA — supplied, installed and commissioned by AxiTech, with preventive maintenance, calibration, troubleshooting, repair and genuine spare parts.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010006853
Category
Shakers, Stirrers & Mixers

Overview

MATRIX Orbital Delta Plus The all-rounder MATRIX Orbital Delta plus mixes, heats and cools reliably with variable inserts. Whether blood samples, pharmaceutical agents, DNA/RNA samples or ELISA assays - reaction vials and plates with even the smallest volumes are reliably mixed and tempered in all laboratory applications. No cross-contamination and an optimal mixing result. In addition, MATRIX Orbital Delta plus comes with numerous user-friendly features: Large and clear display with a convenient menu structure allows for an intuitive operation Firm quick-release fastener for quick and easy changing of the inserts/attachments as well as an automatic attachment detection Quick and effective mixing of liquids with up to 3,000 rpm and 3 mm shaker diameter Reduced waiting time through fast heating and cooling rates of up to 6 °C/min (heating) or 2.5 °C/min at set-point temperature above the ambient temperature (cooling, 0.5 °C/min at set-point temperature between ambient temperature and 15 °C below ambient temperature) Automatic performance of mixing, heating and cooling tasks through programmable ramps Wide range of inserts for reaction vessels and plates Intelligent speed adaption to

Maintenance contract — AxiTech provides planned preventive maintenance for MATRIX Orbital Delta Plus from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair MATRIX Orbital Delta Plus on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Large and clear display with a convenient menu structure allows for an intuitive operation
  • Firm quick-release fastener for quick and easy changing of the inserts/attachments as well as an automatic attachment detection
  • Quick and effective mixing of liquids with up to 3,000 rpm and 3 mm shaker diameter
  • Reduced waiting time through fast heating and cooling rates of up to 6 °C/min (heating) or 2.5 °C/min at set-point temperature above the ambient temperature (cooling, 0.5 °C/min at set-point temperature between ambient temperature and 15 °C below ambient temperature)
  • Automatic performance of mixing, heating and cooling tasks through programmable ramps
  • Wide range of inserts for reaction vessels and plates
  • Intelligent speed adaption to insert, attachment and filling volume
  • Aluminum die cast housing ensures secure positioning, excellent stability and everyday robustness
  • Tempering / mixing of samples
  • Synthesis of cDNA
  • Enzyme-catalysed linking of RNA or DNA (ligation)
  • Lysis reactions
  • Structural change of DNA, RNA and proteins (denaturation)
  • MATRIX Orbital Delta Plus
  • IKA PETTE vario 100-1000 µl

Technical specifications

Specifications
Fuse
2x T4A 250V
Timer
yes
Weight
10 kg
Voltage
100 - 240 V
Frequency
50/60 Hz
Heat output
100 W
Power input
230 W
Speed range
0 - 3000 rpm
Cooling Rate
2.5 °C/min
Heat control
TFT
Heating rate
6 °C/min
Maximum load
0.3 kg
Cooling Power
72 W
Speed display
TFT
Timer display
TFT
USB interface
USB-B
Operating mode
timer, continuous and program operation
Shaking stroke
3 mm
Speed deviation
±30 rpm
Power input max.
230 W
RS 232 interface
yes
Speed adjustment
10 RPM Steps
Type of movement
orbital
Time setting max.
6000 min
Time setting min.
1 s
Motor rating output
88 W
Permissible ON time
100 %
Temperature display
yes
Temperature stability
0.5 °C
Dimensions (W x H x D)
216 x 127 x 351 mm
Speed min (adjustable)
300 rpm
Temperature homogenity
±0.5(@ 20°C ... 45°C) °C
Heating temperature max.
100 °C
Working temperature min.
room temp. -15 °C
Set temperature resolution
±1 °C
Temperature control accuracy
±0.5(@ 20°C ... 45°C) °C
Permissible relative humidity
80 %
Temperature setting range min.
1 °C
Working with microtiter plates
yes
Permissible ambient temperature
5 - 40 °C
Number of exchangable attachments
10
Protection class according to DIN EN 60529
IP 21
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for MATRIX Orbital Delta Plus

AxiTech provides preventive maintenance contracts for MATRIX Orbital Delta Plus. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for MATRIX Orbital Delta Plus

When MATRIX Orbital Delta Plus fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot MATRIX Orbital Delta Plus

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for MATRIX Orbital Delta Plus.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using MATRIX Orbital Delta Plus and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing MATRIX Orbital Delta Plus

AxiTech supplies MATRIX Orbital Delta Plus together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA MATRIX Orbital Delta Plus

Yes. AxiTech services MATRIX Orbital Delta Plus, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.