At a glance

Reference
0025004186
Category
Shakers, Stirrers & Mixers

Overview

RC 2 GREEN basic Powerful, compact and energy-efficient circulating chiller for cooling applications up to -30 °C. The on-demand and speed-controlled compressor, operated with natural refrigerant, achieves a cooling capacity of 800 W at a minimum energy consumption. The speed-controlled PEEK pump allows an indirect continuous adjustment of maximum pressure and flow rate. The integrated filling funnel and drain valve enable safe and clean handling of the thermofluid. With regular cleaning, the easily accessible stainless steel woven mesh air filter guarantees consistent performance. The high-quality insulated 4 l bath reservoir allows the use of up to 2.5 l of thermofluid in the external cooling circle without refilling. highly efficient speed-controlled cooling unit with a cooling capacity of 800 W (@20 °C) natural refrigerant R290 speed-controlled PEEK pump: (0.5 bar; 21 l/min) digital level indicator big LED-Display optical and acoustic warning functions easy-to-clean stainless steel mesh filter high quality insulated 4 l bath reservoir (minimum 1.5 l) Interfaces: RS 232 and USB for controlling and monitoring the devices via labworldsoft® and to update the software online Calibra

Maintenance contract — AxiTech provides planned preventive maintenance for RC 2 GREEN basic from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair RC 2 GREEN basic on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • highly efficient speed-controlled cooling unit with a cooling capacity of 800 W (@20 °C)
  • natural refrigerant R290
  • speed-controlled PEEK pump: (0.5 bar; 21 l/min)
  • digital level indicator
  • big LED-Display
  • optical and acoustic warning functions
  • easy-to-clean stainless steel mesh filter
  • high quality insulated 4 l bath reservoir (minimum 1.5 l)
  • RS 232 and USB for controlling and monitoring the devices via labworldsoft® and to update the software online
  • Calibrateable internal temperature sensor (3 point)
  • RC 2 GREEN basic
  • Olive for DN 8 hoses (2 pcs.)
  • Olive for DN 12 hoses (2 pcs.)
  • USB Cable - USB A to Micro-B, 2 m

Technical specifications

Specifications
Weight
25.5 kg
Voltage
230 V
Frequency
50/60 Hz
Pump type
Pressure- / suction pump
Noise level
61 dB(A)
Power input
350 W
Cooling agent
R290
USB interface
Micro-USB
Appliance type
Recirculating chiller
Filling volume
1.4 - 4.0 l
Pump connection
M16x1
RS 232 interface
yes
Calibration option
yes
Display resolution
0.1 K
Temperature display
yes
Working temperature
-30 - room temp. °C
Sub level protection
yes
Over level protection
yes
Cooling agent quantity
69 g
Dimensions (W x H x D)
220 x 475 x 525 mm
Cooling capacity (@0°C)
500 W
Pump capacity adjustable
yes
Warning function optical
yes
Cooling capacity (@10°C)
700 W
Cooling capacity (@20°C)
800 W
Warning function acoustic
yes
Cooling capacity (@ 10°C)
400 W
Cooling capacity (@ 20°C)
200 W
Cooling capacity (@ 30°C)
90 W
Operating temperature min.
-30 °C
Safety temperature display
LED
Set temperature resolution
0.1 K
Working temperature sensor
PT 100
Cooling agent pressure max.
21 bar
Working temperature display
LED
Permissible relative humidity
80 %
Permissible ambient temperature
5 - 32 °C
Temperature stability DIN 12876
±0.15 K
Warning function excess temperature
yes
Flow rate max. (0 bar back pressure)
21 l/min
Technical data complies with the standard
DIN 12876
Temperature stability DIN 12876 (@ 10°C)
±0.15 K
Protection class according to DIN EN 60529
IP 21
Pressure pump (suction side) (0 liter flow)
0.25 bar
Pump pressure max. (0 liters discharge flow)
0.5 bar
Operating temperature max. (with external heating)
70 °C
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for RC 2 GREEN basic

AxiTech provides preventive maintenance contracts for RC 2 GREEN basic. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for RC 2 GREEN basic

When RC 2 GREEN basic fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot RC 2 GREEN basic

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for RC 2 GREEN basic.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using RC 2 GREEN basic and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing RC 2 GREEN basic

AxiTech supplies RC 2 GREEN basic together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA RC 2 GREEN basic

Yes. AxiTech services RC 2 GREEN basic, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.