RCT basic ETS-D7 Solution — main photograph
IKAAvailability: Supplied to order

RCT basic ETS-D7 Solution

Reference 0010016508

RCT basic ETS-D7 Solution laboratory stirrer from IKA — supplied, installed and commissioned by AxiTech, with preventive maintenance, calibration, troubleshooting, repair and genuine spare parts.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010016508
Category
Shakers, Stirrers & Mixers

Overview

RCT basic ETS-D7 Solution More features, more flexibility – wireless and secure The RCT basic ETS-D7 Solution expands the trusted RCT basic with additional features for wireless temperature and pH measurement. The system combines precise measurement technology with enhanced security and maximum flexibility in everyday laboratory work. Wireless data transmission The USB WD wireless dongle included in the scope of delivery enables the wireless transmission of measurement data. The central system component is the ETS-D7 wireless sensor, also included, which transmits temperature data wirelessly to the RCT basic. A pH electrode can be connected via a BNC connector as an option. The pH value is displayed directly on the ETS-D7 screen. Additionally, the pH value can also be displayed on the RCT basic screen. If required, the ETS-D7 can also be used without the RCT basic as a standalone pH meter or temperature measuring device. Another advantage of wireless sensor technology: No cables on the temperature sensor – damaged or burnt sensor cables are a thing of the past. Alternatively, the Wireless Dongle USB WD also allows connection to the IKA ‘Lab Assistant’ app for visualising measuremen

Maintenance contract — AxiTech provides planned preventive maintenance for RCT basic ETS-D7 Solution from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair RCT basic ETS-D7 Solution on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • PT 1000.60 (wired): Monitoring and limiting the temperature of a heat transfer medium, e.g. synthesis block, oil, water or sand bath
  • ETS-D7: Temperature control directly within the reaction medium
  • RCT basic
  • IKAFLON® 30 Magnetic stirring bar
  • IKAFLON® 40 Magnetic stirring bar
  • ETS-D7 Temperature sensor with display, wireless
  • USB WD USB Dongle RCT
  • H 16 V Support rod
  • PT 1000.60 Temperature sensor, stainless steel
  • H 38 Holding rod
  • H 44 Boss head clamp
  • H 80 Temperature sensor holder
  • Screwdriver

Technical specifications

Specifications
Timer
yes
Weight
2.3 kg
Voltage
220 - 230 V
Frequency
50/60 Hz
Heat output
800 W
Power input
820 W
Speed range
50 - 1500 rpm
Heat control
Control knob (Rotating / Pressing)
Maximum load
25 kg
Timer display
LED
USB interface
USB-C
WPAN interface
optional (USB WD)
PH measurement
optional (with ETS-D7, PT wireless)
Motor principle
Brushless DC
RS 232 interface
yes
Speed adjustment
Control knob (Rotating / Pressing)
Temperature unit
°C
Time setting max.
5999 min
Time setting min.
1 s
Display resolution
0.1 K
Motor rating output
9 W
Power input standby
0.45 W
Stirring bar length
20 - 80 mm
Direction of rotation
right
Set up plate material
Aluminium alloy
Dimensions (W x H x D)
160 x 100 x 200 mm
Setting accuracy speed
10 rpm
Set up plate dimensions
Ø 135 mm
Speed display set value
LED
Adjustable safety circuit
50 - 360 °C
Heating temperature range
Room temp. + device self heating - 310 °C
Temperature setting range
0 - 310 °C
Sensor in medium detection
yes
Speed display actual value
LED
Number of stirring positions
1
Permissible relative humidity
80 %
Temperature display set value
LED
Heating rate (1l H2O in H1500)
9 K/min
Permissible ambient temperature
5 - 40 °C
Temperature display actual value
LED
Temperature measure range PT1000
-20 - 310 °C
PT 1000 deviation;DIN EN 60751 Kl. A
≤ ± (0.15 +0.002xITI) K
Connection for ext. temperature sensor
PT1000, ETS-D5, ETS-D7, PT wireless
Temperature setting resolution of medium
1 K
Protection class according to DIN EN 60529
IP 54
Temperature setting resolution of heating plate
1 K
Operating temperature min. (with external cooling)
-20 °C
Stirring quantity max. per stirring position (H2O)
20 l
Speed deviation (no load,nominal voltage, at 1500rpm + 25 °C)
±2 %
Heat control accuracy of heating plate centre without vessel (at 100°C)
±5 K
Self heating of the set up plate by max. stirring (RT:22°C/duration:1h)
+12 K
Heat control accuracy with ETS D5 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
±0.5 K
Heat control accuracy with ETS D7 (500ml H2O in 600ml beaker, 40mm stirring bar, 600rpm, 50°C)
±0.2 K
Heat control accuracy with ext. PT1000 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
±0.5 K
Heat control accuracy with PT wireless (500ml H2O in 600ml beaker, 40mm stirring bar, 600rpm, 50°C)
±0.2 K
Supply and reordering

AxiTech supplies RCT basic ETS-D7 Solution alongside the instruments it is used with, so a calibration or a service visit never stalls waiting on a consumable.

Ordering RCT basic ETS-D7 Solution

Tell us the reference and the quantity and we come back with a price, a lead time and the batch documentation. Consumables ordered against a maintenance contract are scheduled with the visit, so they arrive with the engineer rather than after them.

  • Batch and expiry documentation supplied with every delivery
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle
Questions we are asked

Frequently asked questions about IKA RCT basic ETS-D7 Solution

Yes. AxiTech supplies RCT basic ETS-D7 Solution to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.

Other IKA equipment we supply, install and maintain.