RCT basic Synthesis Solution 1000 — main photograph
IKAAvailability: Supplied to order

RCT basic Synthesis Solution 1000

Reference 0010016478

RCT basic Synthesis Solution 1000 laboratory stirrer from IKA — AxiTech supports hospitals, clinics and laboratories with sales, installation, maintenance contracts, calibration, repair and spare parts for this equipment.

Order this item

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010016478
Category
Shakers, Stirrers & Mixers

Overview

RCT basic Synthesis Solution 1000 Safe round-bottom flask synthesis with wireless temperature and pH measurement The RCT basic Synthesis Solution 1000 is a complete system solution for safe and controlled synthesis in round-bottom flasks with a volume of up to 1000 ml. It combines the trusted IKA synthesis blocks with modern wireless temperature and pH measurement, as well as enhanced process safety. The use of solid aluminium synthesis blocks significantly reduces potential hazards compared to oil or sand baths and simplifies handling and cleaning. At the same time, costs can be reduced and workflows made more efficient. Wireless temperature and pH measurement in the reaction medium The core component of the system solution is the PT Wireless Sensor, which transmits measured values wirelessly to the RCT basic. In addition to temperature, a pH electrode can also be connected via the BNC port of the PT Wireless as an option. In this configuration, the RCT basic becomes a pH meter – the pH value is displayed directly on the screen, without the need for an additional external instrument. The elimination of sensor cables not only increases flexibility in setup but also reduces typical

Maintenance contract — AxiTech provides planned preventive maintenance for RCT basic Synthesis Solution 1000 from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair RCT basic Synthesis Solution 1000 on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • PT 1000.60 (wired): Temperature monitoring and limitation of the synthesis block or heat carrier
  • PT Wireless: Temperature control directly in the reaction medium
  • Flask holder for 1000 ml round-bottom flasks
  • Synthesis block made of solid anodised aluminium, temperature-resistant up to 300°C
  • Stand rod and support rod for positioning sensors and accessories
  • Two cross-sockets
  • Universal clamp for secure attachment of the round-bottom flask
  • Elliptical magnetic stir bars, optimally adapted to the shape of the round-bottom flask
  • RCT basic
  • PT wireless Wireless Sensor
  • H 135.40 Flask carrier 1000 ml without handle
  • R 350 Universal clamp
  • USB WD USB RCT Dongle
  • H 38 Holding rod
  • H 44 Boss head clamp (2 pcs.)
  • PT 1000.60 Temperature sensor, stainless steel
  • IKAFLON 25 ellipse (5 pcs.)
  • IKAFLON® 30 Magnetic stirring bar
  • IKAFLON® 40 Magnetic stirring bar
  • H 16 V Support rod
  • H 80 Temperature sensor holder
  • Screwdriver

Technical specifications

Specifications
Timer
yes
Weight
2.3 kg
Voltage
220 - 230 V
Frequency
50/60 Hz
Heat output
800 W
Power input
820 W
Speed range
50 - 1500 rpm
Heat control
Control knob (Rotating / Pressing)
Maximum load
25 kg
Timer display
LED
USB interface
USB-C
WPAN interface
optional (USB WD)
PH measurement
optional (with ETS-D7, PT wireless)
Motor principle
Brushless DC
RS 232 interface
yes
Speed adjustment
Control knob (Rotating / Pressing)
Temperature unit
°C
Time setting max.
5999 min
Time setting min.
1 s
Display resolution
0.1 K
Motor rating output
9 W
Power input standby
0.45 W
Stirring bar length
20 - 80 mm
Direction of rotation
right
Set up plate material
Aluminium alloy
Dimensions (W x H x D)
160 x 100 x 200 mm
Setting accuracy speed
10 rpm
Set up plate dimensions
Ø 135 mm
Speed display set value
LED
Adjustable safety circuit
50 - 360 °C
Heating temperature range
Room temp. + device self heating - 310 °C
Temperature setting range
0 - 310 °C
Sensor in medium detection
yes
Speed display actual value
LED
Number of stirring positions
1
Permissible relative humidity
80 %
Temperature display set value
LED
Heating rate (1l H2O in H1500)
9 K/min
Permissible ambient temperature
5 - 40 °C
Temperature display actual value
LED
Temperature measure range PT1000
-20 - 310 °C
PT 1000 deviation;DIN EN 60751 Kl. A
≤ ± (0.15 +0.002xITI) K
Connection for ext. temperature sensor
PT1000, ETS-D5, ETS-D7, PT wireless
Temperature setting resolution of medium
1 K
Protection class according to DIN EN 60529
IP 54
Temperature setting resolution of heating plate
1 K
Operating temperature min. (with external cooling)
-20 °C
Stirring quantity max. per stirring position (H2O)
20 l
Speed deviation (no load,nominal voltage, at 1500rpm + 25 °C)
±2 %
Heat control accuracy of heating plate centre without vessel (at 100°C)
±5 K
Self heating of the set up plate by max. stirring (RT:22°C/duration:1h)
+12 K
Heat control accuracy with ETS D5 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
±0.5 K
Heat control accuracy with ETS D7 (500ml H2O in 600ml beaker, 40mm stirring bar, 600rpm, 50°C)
±0.2 K
Heat control accuracy with ext. PT1000 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
±0.5 K
Heat control accuracy with PT wireless (500ml H2O in 600ml beaker, 40mm stirring bar, 600rpm, 50°C)
±0.2 K
Supply and reordering

AxiTech supplies RCT basic Synthesis Solution 1000 alongside the instruments it is used with, so a calibration or a service visit never stalls waiting on a consumable.

Ordering RCT basic Synthesis Solution 1000

Tell us the reference and the quantity and we come back with a price, a lead time and the batch documentation. Consumables ordered against a maintenance contract are scheduled with the visit, so they arrive with the engineer rather than after them.

  • Batch and expiry documentation supplied with every delivery
  • Quoted with a lead time, not just a price
  • Scheduled with your maintenance visit when you hold a contract
  • Standing orders for items you consume on a predictable cycle

The instrument it is used with

AxiTech maintains, calibrates and repairs the IKA equipment that RCT basic Synthesis Solution 1000 is used with. If you operate it, we can put it under a preventive maintenance contract and supply this item as part of the schedule.

Discover our maintenance contractsBrowse the equipment catalogue

Questions we are asked

Frequently asked questions about IKA RCT basic Synthesis Solution 1000

Yes. AxiTech supplies RCT basic Synthesis Solution 1000 to hospitals, clinics and laboratories, either as a one-off order or on a standing schedule. Send us the reference and the quantity and we come back with a price and a lead time.

Other IKA equipment we supply, install and maintain.