RH lite

Reference 0020007108

RH lite laboratory stirrer from IKA — supplied, installed and commissioned by AxiTech, with preventive maintenance, calibration, troubleshooting, repair and genuine spare parts.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0020007108
Category
Shakers, Stirrers & Mixers

Overview

RH lite Simple. Compact. Reliable. The new RH lite is the perfect solution for entering the world of magnetic stirrers. It impresses with its compact design and high-quality at an affordable price. Developed for simple applications and basic laboratory needs, it combines an attractive price-performance ratio with solid quality and clever functionality. RH lite offers everything you need for safe and efficient work. High performance for little money Adjustable temperature safety circuit in accordance with laboratory equipment standard EN IEC 61010-2-010 for heated devices Two rotary and push buttons for independent setpoint adjustment and start/stop of the heating and stirring function 600 W heating power Robust 135 mm aluminum heating plate with increased surface strength for long service life Maximum temperature: 310 °C for a wide range of applications Energy-efficient EC motor For powerful stirring with minimal energy consumption up to 1500 rpm Extremely compact design: only 168 × 217 mm – ideal for small work surfaces Low self-heating of the heating plate perfect for mixing temperature-sensitive samples Two tripod mounting points for flexible use and a secure test setup What it

Maintenance contract — AxiTech provides planned preventive maintenance for RH lite from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair RH lite on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • Adjustable temperature safety circuit in accordance with laboratory equipment standard EN IEC 61010-2-010 for heated devices
  • Two rotary and push buttons for independent setpoint adjustment and start/stop of the heating and stirring function
  • 600 W heating power
  • Robust 135 mm aluminum heating plate with increased surface strength for long service life
  • Maximum temperature: 310 °C for a wide range of applications
  • Energy-efficient EC motor For powerful stirring with minimal energy consumption up to 1500 rpm
  • Extremely compact design: only 168 × 217 mm – ideal for small work surfaces
  • Low self-heating of the heating plate perfect for mixing temperature-sensitive samples
  • Two tripod mounting points for flexible use and a secure test setup
  • RH lite
  • IKAFLON® 30 Magnetic stirring bar
  • Screwdriver

Technical specifications

Specifications
Weight
2.1 kg
Voltage
220 - 230 V
Frequency
50/60 Hz
Heat output
600 W
Power input
620 W
Speed range
100 - 1500 rpm
Heat control
Turning knob
Maximum load
20 kg
Motor principle
Brushless DC
Speed adjustment
Turning knob
Temperature unit
°C
Motor rating output
7 W
Stirring bar length
20 - 80 mm
Direction of rotation
right
Set up plate material
Aluminium alloy
Dimensions (W x H x D)
168 x 100 x 217 mm
Set up plate dimensions
Ø 135 mm
Speed display set value
scale
Adjustable safety circuit
50 - 360 °C
Heating temperature range
Room temp. + device self heating - 310 °C
Temperature setting range
0 - 310 °C
Speed display actual value
scale
Number of stirring positions
1
Permissible relative humidity
80 %
Temperature display set value
scale
Heating rate (1l H2O in H1500)
5.5 K/min
Permissible ambient temperature
5 - 40 °C
Temperature display actual value
scale
Protection class according to DIN EN 60529
IP 22
Stirring quantity max. per stirring position (H2O)
15 l
Speed deviation (no load,nominal voltage, at 1500rpm + 25 °C)
±5 %
Heat control accuracy of heating plate centre without vessel (at 100°C)
±5 K
Heat control accuracy of heating plate centre without vessel (at 300°C)
±15 K
Self heating of the set up plate by max. stirring (RT:22°C/duration:1h)
+6 K
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for RH lite

AxiTech provides preventive maintenance contracts for RH lite. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for RH lite

When RH lite fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot RH lite

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for RH lite.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using RH lite and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing RH lite

AxiTech supplies RH lite together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA RH lite

Yes. AxiTech services RH lite, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.