ROTAVISC lo-vi HELI Complete — main photograph
IKAAvailability: Supplied to order

ROTAVISC lo-vi HELI Complete

Reference 0010013698

ROTAVISC lo-vi HELI Complete laboratory stirrer from IKA — AxiTech supports hospitals, clinics and laboratories with sales, installation, maintenance contracts, calibration, repair and spare parts for this equipment.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010013698
Category
Shakers, Stirrers & Mixers

Overview

ROTAVISC lo-vi HELI Complete Regardless of a simple or demanding viscosity measurement - IKA ROTAVISC lo-vi HELI Complete determines the viscosity of low-viscosity liquids in all areas of application ranging from the laboratory to quality control. The scope of delivery includes a standard spindle set (SP 1-SP 4), a protective bracket, temperature sensor and HELISTAND stand incl. T-spindle set. Easy to operate The generous 4.3″ TFT display allows for an intuitive menu guidance. A digital spirit level also supports the correct set-up of the start-up condition. The simple ramp function simplifies repetitive tasks. Highest measurement accuracy The level of measurement accuracy of the ROTAVISC rotational viscometer for both Newtonian and non-Newtonian fluids is +/- 1 % of the measuring range. The reproducibility is +/- 0.2 %. Stepless speed ROTAVISC is a viscometer, which offers stepless speed adjustment. Viscosity measurement in motion The motorized IKA HELISTAND moves the mounted viscometer and its rotating body slowly and uniformly up and down in the sample IKA ROTAVISC lo-vi HELI Complete Viscosity measuring range: 15 - 6.000.000 mPas Scope of delivery ROTAVISC lo-vi HELI Complete S

Maintenance contract — AxiTech provides planned preventive maintenance for ROTAVISC lo-vi HELI Complete from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair ROTAVISC lo-vi HELI Complete on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • ROTAVISC lo-vi HELI Complete
  • SP set-1
  • PT 100.8
  • HELISTAND
  • T-SP-SET

Technical specifications

Specifications
Stand
HELISTAND
Timer
yes
Weight
7.1 kg
Display
TFT
Voltage
100 - 240 V
Diameter
16 mm
Frequency
50/60 Hz
DC Voltage
24 V=
Guard rail
lo-vi
Power input
24 W
Speed range
0.01 - 200 rpm
Stroke max.
61 mm
Dynamic load
3.2 kg
Speed display
TFT
Spring torque
0.0673 mNm
Timer display
TFT
USB interface
Micro-USB
Graph function
yes
Operating mode
timer and continuous operation
Torque display
yes
Touch function
yes
Pemitted density
9999 kg/dm3
RS 232 interface
yes
Speed adjustment
TFT
Calibration option
yes
Fastening on stand
extension arm
Time setting range
0.017 - 6000 min
Torque measurement
yes
Current consumption
1000 mA
Motor rating output
4.8 W
Overload protection
yes
Power input standby
0.06 W
Working temperature
-100 - 300 °C
Direction of rotation
right
Plug in coupling (Ø)
12 mm
Basic container volume
600 ml
Dimensions (W x H x D)
351 x 629 x 372 mm
Setting accuracy speed
±0.01 rpm
Telescope stand stroke
142 mm
Measuring spindle series
SP set-1
Viscosity Accuracy (FSR)
1 %
Viscosity Measuring Range
6000000 mPas
Working temperature display
TFT
Permissible relative humidity
80 %
Viscosity Repeatibility (FSR)
0.2 %
Permissible ambient temperature
5 - 40 °C
Temperature measurement resolution
0.1 K
Connection for ext. temperature sensor
PT 100
Protection class according to DIN EN 60529
IP 40
Support rod diameter (with integrated fastening on stand)
16 mm
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for ROTAVISC lo-vi HELI Complete

AxiTech provides preventive maintenance contracts for ROTAVISC lo-vi HELI Complete. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for ROTAVISC lo-vi HELI Complete

When ROTAVISC lo-vi HELI Complete fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot ROTAVISC lo-vi HELI Complete

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for ROTAVISC lo-vi HELI Complete.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using ROTAVISC lo-vi HELI Complete and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing ROTAVISC lo-vi HELI Complete

AxiTech supplies ROTAVISC lo-vi HELI Complete together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA ROTAVISC lo-vi HELI Complete

Yes. AxiTech services ROTAVISC lo-vi HELI Complete, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.