RV 10 auto pro V-C — main photograph
IKAAvailability: Supplied to order

RV 10 auto pro V-C

Reference 0010004812

RV 10 auto pro V-C laboratory stirrer from IKA — supplied, installed and commissioned by AxiTech, with preventive maintenance, calibration, troubleshooting, repair and genuine spare parts.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
0010004812
Category
Shakers, Stirrers & Mixers

Overview

RV 10 auto pro V-C The completely revised RV 10 auto is the flagship of the IKA rotatary evaporator product line. Its features include an innovative handling concept with a bright, high-contrast, TFT, color-graphic control panel, an integrated vacuum controller, cooling water monitoring and mature safety standards. The RV 10 auto offer all properties required for efficient, safe, and cost-effective operations. These include automatic control of the vacuum and cooling water volume. Its intuitive handling concept quickly leads its users to their desired results in every application. Thanks to specially designed glass guides, the transparent coated vertical condenser makes extremely efficient use of the 1500 cm² cooling surface. Thanks to its extended ramp programming capability, the RV 10 auto allows users to carry out customized procedures. Other innovative features, such as smooth start, interval mode, right-left operation in interval mode, or the timer function for time-lapse tests, make everyday work in the laboratory much easier. Safety is ensured by the motorized lift with safety-stop function that automatically lifts the evaporation flask out of the heating bath in the case of

Maintenance contract — AxiTech provides planned preventive maintenance for RV 10 auto pro V-C from IKA: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our shakers, stirrers & mixers engineers diagnose and repair RV 10 auto pro V-C on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Features

  • 4-liter heating bath with a heating temperature range of RT to 180 °C
  • automatic boiling point detection
  • integrated vacuum controller
  • integrated solvent library with 40 preset solvents and expansion option
  • bright, high-contrast, TFT, color-graphic control panel
  • universal safety heating bath
  • optimized heating bath volume for rapid achievement of working temperature
  • heating bath with ergonomic handles
  • temperature safety circuit
  • boil-dry protection
  • condenser with 1500 cm² cooling surface and low space requirements
  • evaporation flasks available with coated or uncoated glass
  • intuitive handling concept with simple menu navigation
  • programming option for up to ten individual procedures
  • smooth start
  • right or left rotation
  • timer function
  • end-point recognition
  • push-off mechanism for tightly-fitting flasks
  • digital interfaces: USB port and RS-232 interface for remote control
  • multi-language operating system
  • automatic cooling water management
  • automatic ventilation
  • automatic heating bath management
  • RV 10 auto pro FLEX
  • VACSTAR digital
  • RV 10.10 Glassware vertical coated
  • RV 10.88 Clamp NS 29
  • RV 10.70 Vapor tube (NS 29/32)
  • RV 10.8001 Seal
  • Vacuum hose (2 x 0.55 m)
  • Water discharge hose (1 x 1 m)
  • USB cable

Technical specifications

Specifications
Lift
Motor
Timer
yes
Stroke
140 mm
Weight
52.65 kg
Voltage
100 - 240 V
Frequency
50/60 Hz
Heat output
1350 W
Power input
100 W
Speed range
5 - 300 rpm
Analog output
yes
USB interface
Micro-USB
Cooling surface
1500 cm2
Type of cooling
Vertical condenser
RS 232 interface
yes
Filling volume max.
4 l
Power input standby
3.3 W
Dimensions (W x H x D)
500 x 430 x 440 mm
Measurement accuracy +/
1 mbar
Heating temperature range
room temp. - 180 °C
Set temperature resolution
1 K
Vacuum controller integrated
yes
Permissible relative humidity
80 %
Permissible ambient temperature
5 - 40 °C
Reversible direction of rotation
yes
Protection class according to DIN EN 60529
IP 20
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for RV 10 auto pro V-C

AxiTech provides preventive maintenance contracts for RV 10 auto pro V-C. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Plan at least one preventive maintenance visit per year, and a second visit for equipment in continuous or critical use.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for RV 10 auto pro V-C

When RV 10 auto pro V-C fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The faults we see most often are worn moving parts, power-supply and control-board failures, sensors that have drifted out of tolerance, and fluid or air paths that have become blocked or contaminated.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot RV 10 auto pro V-C

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Confirm the power supply end to end — wall outlet, mains lead, fuse and any UPS or stabiliser in between. A device that is intermittently dead has a supply fault far more often than an internal one.

  3. Check the consumables and wear parts — filters, seals, tubing, probes, batteries — and note when each was last replaced. Anything past its service interval is the first suspect.

  4. Reproduce the fault once, deliberately, and record the sequence: what the operator did, what the device displayed, and whether a full power cycle clears it.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for RV 10 auto pro V-C.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using RV 10 auto pro V-C and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing RV 10 auto pro V-C

AxiTech supplies RV 10 auto pro V-C together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Questions we are asked

Frequently asked questions about IKA RV 10 auto pro V-C

Yes. AxiTech services RV 10 auto pro V-C, either under a maintenance contract or as a one-off intervention. Our biomedical engineers cover preventive maintenance, calibration, corrective repair and spare-parts supply for this equipment.

Other IKA equipment we supply, install and maintain.