Hot Air Sterilizer — main photograph
LabTechAvailability: Supplied to order

Hot Air Sterilizer

Reference 2571618

Hot air steriliser by LabTech: temperature range Ambient 15 °C – 250 °C.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571618
Category
Hot Air & Dry Heat Sterilizers
Product range
Hot Air Sterilizers

Features

  • Temp. range: Ambient 15℃ ~ 250℃
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for LabTech Hot Air Sterilizer

A service visit on the LabTech Hot Air Sterilizer covers temperature calibration and a uniformity check across the chamber, the door seals, fans and heating elements, the over-temperature protection and alarms, and — on CO₂ or humidity-controlled models — the gas and humidity sensors.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Incubators, ovens and climate chambers like the LabTech Hot Air Sterilizer are normally calibrated once a year; chambers used for stability studies or GMP work are temperature-mapped at the interval their qualification sets.

  • Temperature calibration and uniformity check across the chamber
  • Door seals, fans and heating elements inspected
  • Over-temperature protection and alarms tested
  • CO₂, O₂ or humidity sensors calibrated where fitted

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for LabTech Hot Air Sterilizer

When LabTech Hot Air Sterilizer fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On incubators, ovens and chambers the common faults are worn door seals, failed fans or heating elements, temperature sensors that have drifted, CO₂ sensors out of calibration, and controllers that lose their settings.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot LabTech Hot Air Sterilizer

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Check the door seal and that the door closes fully: frequent or long openings are the most common cause of temperature and CO₂ excursions.

  3. Place an independent thermometer in the centre of the chamber and compare it with the display once the chamber has stabilised.

  4. Confirm the over-temperature safety setting and the fan operation and, on CO₂ models, the gas supply pressure and cylinder level.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for LabTech Hot Air Sterilizer.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using LabTech Hot Air Sterilizer and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing LabTech Hot Air Sterilizer

AxiTech supplies LabTech Hot Air Sterilizer together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the LabTech Hot Air Sterilizer

Key specifications of the LabTech Hot Air Sterilizer, according to the manufacturer: temperature range Ambient 15 °C – 250 °C.

Other LabTech equipment we supply, install and maintain.