Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) — main photograph
LabTechAvailability: Supplied to order

Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

Reference 2571514

Steam steriliser by LabTech: sterilisation temperature 121 °C – 135 °C; chamber volume 200L, 300L.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571514
Category
Autoclaves & Steam Sterilizers
Product range
Steam Sterilizers

Overview

Large Steam Sterilizer - Front LoadingClass B SterilizationPre & Post Vacuum System

A built-in vacuum pump enables pre-vacuum air removal for efficient steam penetration and post-vacuum drying at the end of a cycle for drying the remaining steam

Reinforced and electro-polished stainless steel chamber for excellent corrosion resistance, long lasting, and efficient in space using (Option: STS 316L Chamber)

A built-in separate steam generator supplies water automatically and provides better drying condition after sterilization

0.2 um HEPA filter is installed for clean air to flow into the chamber to protect from air contamination and to cool down the chamber

After a cycle is finished, the user can print out the cycle performance with a printer that is equipped as standard With front loading type, it's more convenient to load

Sturdy and convenient locking castors are installed for easy moving and fixing

7 in. touch screen controller is equipped to provide easy and convenient operation

Self-diagnostic and error display system alerts, displays error codes, and stops operating with automatic ventilation in case of any malfunction Emergency stop button is equipped for user safety in case of emergency situation

For safety of the users, the cycle will not start if

Features

  • Capacity : 200ℓ, 300ℓ
  • Sterilizer Temp.: 121℃ ~135℃
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

A service visit on the LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) covers calibration of the temperature and pressure sensors, the door seal, lock and safety valve, the steam generator, vacuum system, drains and filters, and a recorded test cycle.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Steam sterilisers like the LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) are normally serviced once or twice a year and revalidated every year, while users run the routine tests their class requires — for Class B units, a daily steam-penetration (Bowie-Dick or Helix) test and a regular vacuum leak test.

  • Temperature and pressure sensors calibrated
  • Door seal, locking mechanism and safety valve checked
  • Steam generator descaled, filters and drains cleaned
  • Test cycles run and recorded, including vacuum leak and Bowie-Dick tests on Class B models

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

When LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On steam sterilisers the common faults are failing door seals and locks, scale in the steam generator, blocked drains and filters, vacuum pumps that no longer reach their set point, and drifting temperature or pressure sensors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Inspect and clean the door gasket and the chamber drain filter: debris on either causes most pressure and vacuum errors.

  3. Check the water quality and level in the reservoir — tap water or a low level leads to scale, heating faults and aborted cycles.

  4. Run the manufacturer's test cycle (vacuum leak or Bowie-Dick test on Class B models) and keep the printout for the engineer.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L).

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

AxiTech supplies LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L) together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L)

Key specifications of the LabTech Large Steam Sterilizer - Front Loading, Class B (200 / 300 L), according to the manufacturer: sterilisation temperature 121 °C – 135 °C; chamber volume 200L, 300L.

Other LabTech equipment we supply, install and maintain.