Plasma Low Temp. Sterilizer - Benchtop Type (56 L) — main photograph
LabTechAvailability: Supplied to order

Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

Reference 2571519

Low-temperature plasma steriliser by LabTech: sterilisation temperature Max. 60 °C; chamber volume 56L.

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571519
Category
Plasma & Low-Temperature Sterilizers
Product range
Plasma Sterilizers

Overview

Plasma Low Temp. Sterilizer- Benchtop TypeSterilization Temp. 35℃~60℃

Labtech plasma sterilizer is designed andmanufactured on the basis of long years accumulatedvacuum & plasma technology with sterilizing agenthydrogen peroxide in order to sterilize medicalinstruments at low temperature status without leavingtoxic residueIt is very practical and suitable for sterilization of all kindsof medical instrument and materials which can not with-stand high temperature and steam pressure, speciallyricsrigid and flexible endoscopesBuilt in plasma generator discharges plasma arc in orderto dissolve H2O2 into water and oxgen as well as cleansterile products surface harm of H2O2 residue for safetyFor perfect sterilization performance, we install highcapacity vacuum pump equipped with high qualitystainless steel vacuum piping parts and valves so thatit produce optimum vacuum degree to make plasmastatus in the chamber

With front loading type, it's more convenient to loadManual open/closure, Automatic inter lockmechanism

For durability of vacuum pump and degree, weinstall special absorption trap between chamberand vacuum pump in order to collect any inflow ofHydrogen peroxide and water in the process of vacuumdiffusion and gas removal. It protects vacuum pumpfrom damage and degradation

After sterilization, medical equipments can beused immediately. This increases the number of useper day as well as reduces user's inventory costs andmaintenance feeSpeedy sterilization processes which are completedwithin 30-60 min.

After a cycle is finished, the user can print out the cycleperformance with a printer that is equipped as standard

Fully automatic operation with colortouch screen with LED process display7 in. touch screen controller is equipped to provideeasy and convenient operationSelf-diagnostic and error display system alerts,displays error codes, and stops operating withautomatic ventilation in case of any malfunctionFor safety of the users, the door will not open at theend of cycle if the chamber is pressurized Manual doorlocking system to ensure user safetyTemperature auto-tuning function availableTime 99hr.59min. availabe (Timer and alarm available)Visible and audible alarmSetting value is preserved even when the powersupplyis cut

Features

  • Capacity: 56ℓ
  • Sterilizer Temperature: Max. 60℃
Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

A service visit on the LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L) covers the vacuum system and chamber leak rate, the hydrogen-peroxide delivery and plasma generation, calibration of the chamber temperature and pressure sensors, and a process challenge with chemical and biological indicators.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Low-temperature plasma sterilisers like the LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L) are normally serviced once or twice a year, with every load monitored by chemical indicators and routine biological indicator tests as your sterilisation policy requires.

  • Vacuum pump and chamber leak rate tested
  • Hydrogen-peroxide delivery and plasma system checked
  • Temperature and pressure sensors calibrated
  • Process verified with chemical and biological indicators

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

When LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L) fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

The usual faults on plasma sterilisers are cycles aborted by moisture left on instruments, vacuum problems, expired or incorrectly loaded sterilant cartridges, and plasma or heater faults.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Make sure every instrument is completely dry and free of cellulose (paper, cotton, linen): moisture and cellulose are the most common causes of aborted cycles.

  3. Check that the sterilant cartridge is in date, correctly inserted and not exhausted.

  4. Reduce the load to the manufacturer's limit and rerun the cycle; if it still cancels, note the cancel code for the engineer.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L).

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L) and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

AxiTech supplies LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L) together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training
Product FAQ

Questions about the LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L)

Key specifications of the LabTech Plasma Low Temp. Sterilizer - Benchtop Type (56 L), according to the manufacturer: sterilisation temperature Max. 60 °C; chamber volume 56L.

Other LabTech equipment we supply, install and maintain.