Plasma Low Temp. Sterilizer ‌- Benchtop Type — main photograph
LabTechAvailability: Supplied to order

Plasma Low Temp. Sterilizer ‌- Benchtop Type

Reference 2571519

· Sterilizer Temperature: Max. 60℃· Capacity: 56ℓ

Request a service for this equipment

Nothing is charged online. Every request is reviewed by an AxiTech engineer before you receive a quotation.

At a glance

Reference
2571519
Category
Plasma & Low-Temperature Sterilizers
Equipment family
Plasma Sterilizers

Overview

Plasma Low Temp. Sterilizer‌- Benchtop TypeSterilization Temp. 35℃~60℃ Catalog Download

Labtech plasma sterilizer is designed andmanufactured on the basis of long years accumulatedvacuum & plasma technology with sterilizing agenthydrogen peroxide in order to sterilize medicalinstruments at low temperature status without leavingtoxic residueIt is very practical and suitable for sterilization of all kindsof medical instrument and materials which can not with-stand high temperature and steam pressure, speciallyricsrigid and flexible endoscopesBuilt in plasma generator discharges plasma arc in orderto dissolve H2O2 into water and oxgen as well as cleansterile products surface harm of H2O2 residue for safetyFor perfect sterilization performance, we install highcapacity vacuum pump equipped with high qualitystainless steel vacuum piping parts and valves so thatit produce optimum vacuum degree to make plasmastatus in the chamber

With front loading type, it's more convenient to loadManual open/closure, Automatic inter lockmechanism

For durability of vacuum pump and degree, weinstall special absorption trap between chamberand vacuum pump in order to collect any inflow ofHydrogen peroxide and water in the process of vacuumdiffusion and gas removal. It protects vacuum pumpfrom damage and degradation

After sterilization, medical equipments can beused immediately. This increases the number of useper day as well as reduces user's inventory costs andmaintenance feeSpeedy sterilization processes which are completedwithin 30-60 min.

After a cycle is finished, the user can print out the cycleperformance with a printer that is equipped as standard

Fully automatic operation with colortouch screen with LED process display7 in. touch screen controller is equipped to provideeasy and convenient operationSelf-diagnostic and error display system alerts,displays error codes, and stops operating withautomatic ventilation in case of any malfunctionFor safety of the users, the door will not open at theend of cycle if the chamber is pressurized Manual doorlocking system to ensure user safetyTemperature auto-tuning function availableTime 99hr.59min. availabe (Timer and alarm available)Visible and audible alarmSetting value is preserved even when the powersupplyis cut

Maintenance contract — AxiTech provides planned preventive maintenance for Plasma Low Temp. Sterilizer ‌- Benchtop Type from LabTech: scheduled visits, safety checks, periodic calibration and a documented service report, backed by a contractual response time.

Troubleshooting, repair and spare parts — our laboratory & ivd engineers diagnose and repair Plasma Low Temp. Sterilizer ‌- Benchtop Type on site or in the workshop, fit genuine spare parts and recommission the equipment after performance verification.

Service coverage

AxiTech maintains, repairs and supplies this equipment for hospitals, clinics, laboratories and imaging centres.

Maintenance contracts for Plasma Low Temp. Sterilizer ‌- Benchtop Type

AxiTech provides preventive maintenance contracts for Plasma Low Temp. Sterilizer ‌- Benchtop Type. Each contract fixes a schedule of planned visits in which our biomedical engineers inspect the equipment, replace wear parts before they fail, and verify that it still performs inside the manufacturer’s tolerances.

Every visit includes calibration and performance verification, and closes with a documented maintenance report you can present during an accreditation audit. Spare-parts availability and a guaranteed response time are written into the contract, so a breakdown never leaves a department waiting for an answer.

Laboratory analysers are usually maintained every three to six months, with calibration and quality-control verification at each visit so that results stay traceable.

  • Planned preventive maintenance visits at a fixed interval
  • Calibration and performance verification against the manufacturer’s specifications
  • A documented maintenance report after every intervention
  • Guaranteed availability of spare parts and consumables
  • A contractual response time when the equipment fails

Discover our maintenance contracts

Planned preventive maintenance and calibration under contract

Troubleshooting and repair for Plasma Low Temp. Sterilizer ‌- Benchtop Type

When Plasma Low Temp. Sterilizer ‌- Benchtop Type fails, our engineers start with a structured diagnostic: error codes, electrical and mechanical checks, and a functional test against the equipment’s own specification. That tells us whether the fault is a consumable, a worn part or a board-level failure before any part is ordered.

Straightforward faults are repaired on site so the department loses as little time as possible. Anything that needs a workbench, a full strip-down or a specialised spare part goes to our workshop and comes back only after a complete post-repair test and, where the equipment requires it, recalibration.

Faults we see most often on this type of equipment

On analysers most faults come from the fluidics — blocked probes, worn pumps and tubing, leaking valves — followed by optical drift and reagent-handling errors.

Discover our troubleshooting and repair service

Diagnostics, corrective repair and spare parts in the workshop
Troubleshooting

How to troubleshoot Plasma Low Temp. Sterilizer ‌- Benchtop Type

Work through these checks before you escalate. They are the same first-line sequence our biomedical engineers run on arrival, and they either clear the fault or narrow it down enough that the intervention starts with the right spare part in the van.

  1. Capture the fault before you touch anything: write down the exact error code or message, the serial number from the rating plate, what the operator was doing and whether the fault clears on a restart.

  2. Review the quality-control and calibration history. A result that has drifted across several runs points at calibration or reagents; a sudden shift almost always points at the fluidics.

  3. Inspect the fluid path — probe, tubing, pump, valves and waste line — for blockage, crystallisation or leaks, and confirm reagent and wash levels together with their expiry dates.

  4. Confirm the ambient conditions the method depends on: bench temperature, ventilation, a level and vibration-free surface, and a stable mains supply.

  5. If the fault is still there, escalate with the evidence. Send AxiTech the model, serial number, error code and the checks you have already run, and an engineer will come back with a diagnosis, a repair quote and a spare-parts lead time for Plasma Low Temp. Sterilizer ‌- Benchtop Type.

What to send us when you report the fault

  • Manufacturer, model and serial number, from the rating plate
  • The exact error code or message, and the screen it appears on
  • When the fault started, how often it occurs and what triggers it
  • A photograph of the display or of the fault, and the last maintenance report

If the fault survives all five steps, stop using Plasma Low Temp. Sterilizer ‌- Benchtop Type and open a repair request. Continuing to run equipment through a fault it cannot clear turns a component failure into a board-level one, and on devices used for diagnosis or therapy it puts the result — and the patient — in doubt.

Discover our troubleshooting and repair service

Buying and installing Plasma Low Temp. Sterilizer ‌- Benchtop Type

AxiTech supplies Plasma Low Temp. Sterilizer ‌- Benchtop Type together with the accessories and consumables it needs to enter service. We handle importation, delivery and installation, then commission the equipment on site so that it is verified against its specification before the first patient or the first sample.

Installation is followed by training for the users and for your biomedical team, warranty registration, and — if you want it — a maintenance contract that takes over the day the warranty ends, so the equipment never spends a period without planned service.

Discover our equipment sales service

Delivery, installation, commissioning and user training